Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

4.1. Description of first aid measures

First aid personnel should pay attention to their own safety. If the patient is likely to become

unconscious, place and transport in stable sideways position (recovery position). Immediately

remove contaminated clothing.

If inhaled:

Keep patient calm, remove to fresh air, seek medical attention. Immediately administer a

corticosteroid from a controlled/metered dose inhaler.

On skin contact:

Immediately wash thoroughly with plenty of water, apply sterile dressings, consult a skin specialist.

On contact with eyes:

Immediately wash affected eyes for at least 15 minutes under running water with eyelids held open,

consult an eye specialist.

On ingestion:

Immediately rinse mouth and then drink 200-300 ml of water, seek medical attention.

4.2. Most important symptoms and effects, both acute and delayed

Symptoms: The most important known symptoms and effects are described in the labelling (see

section 2) and/or in section 11., Further symptoms are possible

4.3. Indication of any immediate medical attention and special treatment needed

Treatment: Treat according to symptoms (decontamination, vital functions), no known specific

antidote.

Fire-fighting measures

5.1. Extinguishing media

Suitable extinguishing media:

water spray, dry powder, foam, carbon dioxide

5.2. Special hazards arising from the substance or mixture

nitrogen oxides, carbon oxides

The substances/groups of substances mentioned can be released in case of fire. Under certain

conditions in case of fire other hazardous combustion products may be generated.

5.3. Advice for fire-fighters

Special protective equipment:

Wear self-contained breathing apparatus and chemical-protective clothing.

Further information:

Dispose of fire debris and contaminated extinguishing water in accordance with official regulations.

Accidental release measures

6.1. Personal precautions, protective equipment and emergency procedures

Avoid inhalation. Avoid contact with the skin, eyes and clothing.

6.2. Environmental precautions

Do not discharge into drains/surface waters/groundwater.

6.3. Methods and material for containment and cleaning up

For small amounts: Pick up with absorbent material (e.g. sand, sawdust, general-purpose binder).

For large amounts: Pick up with suitable appliance and dispose of.

Clean contaminated floors and objects thoroughly with water and detergents, observing

environmental regulations. Collect waste in suitable containers, which can be labeled and sealed.

Incinerate or take to a special waste disposal site in accordance with local authority regulations.

Handling and storage

7.1. Precautions for safe handling

Ensure thorough ventilation of stores and work areas. Product should be worked up in closed

equipment as far as possible. Handle in accordance with good industrial hygiene and safety practice.

When using do not eat, drink or smoke. Hands and/or face should be washed before breaks and at

the end of the shift.

Protection against fire and explosion:

Vapours may form explosive mixture with air. Take precautionary measures against static

discharges. Keep away from sources of ignition - No smoking.

7.2. Conditions for safe storage, including any incompatibilities

Segregate from acids and acid forming substances.

Further information on storage conditions: Containers should be stored tightly sealed in a dry place.

Keep container in a well-ventilated place. Avoid all sources of ignition: heat, sparks, open flame.

Storage stability:

Storage duration: 24 Months

Store at ambient temperature.

From the data on storage duration in this safety data sheet no agreed statement regarding the

warrantee of application properties can be deduced.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

8.1. Control parameters

Components with occupational exposure limits

No occupational exposure limits known.

8.2. Exposure controls

Personal protective equipment

Respiratory protection:

Respiratory protection in case of vapour/aerosol release. Gas filter for gases/vapours of organic

compounds (boiling point >65 °C, e. g. EN 14387 Type A)

Hand protection:

Chemical resistant protective gloves (EN 374)

Suitable materials short-term contact and/or splashes (recommended: At least protective index 2,

corresponding > 30 minutes of permeation time according to EN 374)

nitrile rubber (NBR) - 0.4 mm coating thickness

butyl rubber (butyl) - 0.7 mm coating thickness

Manufacturer's directions for use should be observed because of great diversity of types.

Supplementary note: The specifications are based on tests, literature data and information of glove

manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g.

temperature) it must be considered, that the practical usage of a chemical-protective glove in

practice may be much shorter than the permeation time determined through testing.

Eye protection:

Tightly fitting safety goggles (cage goggles) (e.g. EN 166) and face shield.

Body protection:

Body protection must be chosen depending on activity and possible exposure, e.g. apron, protecting

boots, chemical-protection suit (according to EN 14605 in case of splashes or EN ISO 13982 in case

of dust).

General safety and hygiene measures

Wearing of closed work clothing is required additionally to the stated personal protection equipment.

Handle in accordance with good industrial hygiene and safety practice. Avoid contact with the skin,

eyes and clothing. Avoid inhalation of vapour. Take off immediately all contaminated clothing. Store

work clothing separately.

Stability and reactivity

10.1. Reactivity

No hazardous reactions if stored and handled as prescribed/indicated.

Formation of

flammable gases:

Remarks: Forms no flammable gases in the

presence of water.

10.2. Chemical stability

The product is stable if stored and handled as prescribed/indicated.

10.3. Possibility of hazardous reactions

Strong exothermic reaction with acids.

10.4. Conditions to avoid

Avoid extreme heat. Avoid sources of ignition.

10.5. Incompatible materials

Substances to avoid:

acids, acid anhydrides, oxidizing agents

10.6. Hazardous decomposition products

Possible thermal decomposition products:

carbon monoxide, Carbon dioxide

nitrogen oxides

Disposal considerations

13.1. Waste treatment methods

Incinerate in suitable incineration plant, observing local authority regulations.

A waste code in accordance with the European waste catalog (EWC) cannot be specified, due to

dependence on the usage.

The waste code in accordance with the European waste catalog (EWC) must be specified in

cooperation with disposal agency/manufacturer/authorities.

Contaminated packaging:

Contaminated packaging should be emptied as far as possible; then it can be passed on for