Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-04-03
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
plate method

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of Reaction product of 1-chloro-3-{[1-chloro-3-(dodecyloxy)propan-2-yl]oxy}propan-2-ol with methyl diethanolamine and [3-(dodecyloxy)-2-hydroxypropyl]bis(2-hydroxyethyl)methylammonium chloride
IUPAC Name:
Reaction mass of Reaction product of 1-chloro-3-{[1-chloro-3-(dodecyloxy)propan-2-yl]oxy}propan-2-ol with methyl diethanolamine and [3-(dodecyloxy)-2-hydroxypropyl]bis(2-hydroxyethyl)methylammonium chloride
Test material form:
other: solid, very viscous yellow paste

Results and discussion

Surface tension
Key result
Surface tension:
26.07 mN/m
Temp.:
20 °C
Conc.:
1 g/L
Remarks on result:
other: mean of 2 series, each of 10 measurements

Any other information on results incl. tables

The test item solution was held at constant temperature (20.0 ± 0.5 °C). 59 minutes after conclusion of the first measurement series, a second measurement series was performed for verification purposes. After the first and the second measurement series, the difference between mean values was less than 5%. Therefore no additional measurement series was required.

Measured values test item first series:

Measurement

Time

Mass

Surface Tension

Temperature

No

s

g

mN/m

°C

1

3.0

0.1089

26.57

20.4

2

5.9

0.1067

26.03

20.4

3

8.9

0.1073

26.18

20.4

4

11.9

0.1067

26.03

20.4

5

14.9

0.1068

26.05

20.4

6

17.9

0.1066

26.00

20.4

7

20.9

0.1066

26.00

20.4

8

23.9

0.1064

25.96

20.4

9

26.9

0.1064

25.96

20.4

10

29.9

0.1063

25.93

20.4

Mean

26.07

 

Standard Deviation

0.19

 

 

Measured values test item second series:

Measurement

Time

Mass

Surface Tension

Temperature

No

s

g

mN/m

°C

1

3.0

0.1083

26.42

20.4

2

5.3

0.1064

25.96

20.4

3

8.9

0.1058

25.81

20.4

4

12.0

0.1060

25.86

20.4

5

14.9

0.1060

25.86

20.4

6

17.9

0.1059

25.83

20.5

7

21.0

0.1056

25.76

20.5

8

23.9

0.1057

25.79

20.5

9

26.9

0.1058

25.81

20.5

10

29.9

0.1056

25.76

20.5

Mean

25.89

 

Standard Deviation

0.20

 

During the specified period of time, no significant changes in the surface tension were detected. Values ranging from 25.76 mN/m to 26.57 mN/m were recorded showing no significant variations. The values of the single determinations show no significant difference (0.69 % between mean values of the two measurement series).

Applicant's summary and conclusion

Conclusions:
The surface tension of an aqueous solution of test item was determined as 26.07 ± 0.19 mN/m at 20 ±0.5 °C. As the determined surface tension of test item was lower than 60 mN/m, the test item can be considered as surface active.
Executive summary:

The surface tension of an aqueous solution of the test item was determined according to OECD 115 and EC A.5 using the plate method.

The surface tension of an aqueous solution of the test item was determined as 26.07 ± 0.19 mN/m at 20 ±0.5 °C. One measurement was performed for verification (after 59 minutes). No significant changes and thus no significant dependence on time was observed. As this value is lower than 60 mN/m, the test item was considered as surface active.

The surface tension of the negative control falls within the accepted range.