Administrative data

Endpoint:
vapour pressure
Type of information:
calculation (if not (Q)SAR)
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
not specified
Principles of method if other than guideline:
The vapour pressure of the test item was determined in accordance with the test method OECD Guideline 104 "OECD Guideline For The Testing Of Chemicals, adopted by the Council on 23 rd March 2006, Vapour Pressure" (similar to the test method A.4. "Vapour Pressure according to the Dynamic Method" as described in the Official Journal of the European Communities L383A).
The practical test performance was based on the in-house test procedure VTA(S)31X07001.01: "Determination of the vapour pressure curve of solid and liquid substances by means of DSC".
GLP compliance:
not specified
Type of method:
other: (Grain-Watson estimation

Test material

Constituent 1
Chemical structure
Reference substance name:
Trifluoro(piperidine)boron
EC Number:
209-752-6
EC Name:
Trifluoro(piperidine)boron
Cas Number:
592-39-2
Molecular formula:
C5H11BF3N
IUPAC Name:
piperidine; trifluoroborane
Test material form:
solid: crystalline

Results and discussion

Vapour pressure
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
<= 0 Pa
Vapour pressure at 50°C (if relevant for classification of gas under pressure)
Key result
Vapour pressure:
<= 0.001 Pa

Applicant's summary and conclusion

Conclusions:

The test item BF3-Piperidin-Komplex has a vapour pressure of 4.4*10-6 atm (<=4*10-1 Pa; 4.4*10 -3 mbar) at 20°C and of 1.1*10-4 atm (<= 1.1*101Pa; 1.1*10-1 mbar) at 50°C (the calculation is based on the lowest possible boiling temperature) according to the definition in the OECD Guideline 104 (Grain-Watson estimation)
The experimentally determined vapour pressure of the test item BF3-Piperidin-Komplex at 20 °C (see DSC-diagrams 1, 3 and 4, "Experimental determined vapour pressure curve") is not in the recommended range of 1 to 1000 mbar for DSC-measurements.
Executive summary:

The vapour pressure of the test item was determined in accordance with the test method OECD Guideline 104 "OECD Guideline For The Testing Of Chemicals, adopted by the Council on 23rdMarch 2006, Vapour Pressure" (similar to the test method A.4. "Vapour Pressure according to the Dynamic Method" as described in the Official Journal of the European Communities L383A).

The test item BF3-Piperidin-Komplex has a vapour pressure of 4.4*10-6 atm (<=4*10-1 Pa; 4.4*10 -3 mbar) at 20°C and of 1.1*10-4 atm (<= 1.1*101Pa; 1.1*10-1 mbar) at 50°C (the calculation is based on the lowest possible boiling temperature) according to the definition in the OECD Guideline 104 (Grain-Watson estimation).