Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental start date: 07 January 2016, Experimental completion date: 07 January 2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
2012 (capillary viscometer method)
Deviations:
no
GLP compliance:
no
Remarks:
However, the study was performed in a test facility which has been certified to be in compliance with the principles of GLP.
Type of method:
capillary viscometer (static)
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.997
Remarks on result:
other: Temperature ± 0.5 °C
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.931
Remarks on result:
other: Converted by multiplication of the kinematic (static) viscosity with the density from Envigo study no. MP25FN (0.934 g/cm³)
Temp.:
20°C
Parameter:
other: Fluidity Φ [1/(mPa·s)]
Value:
1.074
Remarks on result:
other: Converted (reciprocal dynamic viscosity)
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.799
Remarks on result:
other: Temperature ± 0.5 °C
Conclusions:
In a reliable and conclusive study according to OECD TG 114 (2012), the kinematic viscosity of the test item was determined to be 0.997 and 0.799 mm²/s at 20.0 and 40 °C (± 0.5 °C), respectively.
Executive summary:

The kinematic viscosity of the test item at 20 and 40 °C was determined in a non-GLP study using the capillary viscometer method according to the OECD TG 114 (2012) protocol. The experiment is considered relevant, adequate and conclusive.

Two determinations were made at both test temperatures. The kinematic viscosity of the test item was found to be 0.997 and 0.799 mm²/s at 20.0 and 40 °C (± 0.5 °C), respectively.

Description of key information

In a valid, reliable and conclusive study according to OECD TG 114 (2012), the kinematic viscosity of the test item was determined to be 0.997 and 0.799 mm²/s at 20.0 and 40 °C (± 0.5 °C), respectively.

Key value for chemical safety assessment

Viscosity:
0.799 mm²/s (static)
at the temperature of:
40 °C

Additional information