Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 7, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Boiling pt.:
> 500 °C
Atm. press.:
1 013 hPa
Decomposition:
no
Remarks on result:
not determinable
Remarks:
no boiling point observed

Melting point / melting range// boiling point / boiling range: DSC measurement

Two DSC measurements with a heating rate of 10 K/min showed no endothermal effect (melting or boiling) in the temperature range of 25 – 500 °C. Both DSC measurements showed an exothermal effect in the temperature range of 450 – 490 °C. The results of the DSC measurements are summarized in Table 1.

Table1: Melting point (DSC measurements)

Ident No.

Test item /

mg

Starting temperature /

°C

Final test temperature /

°C

Temperature range (endo-thermal) /

°C

Onset (melting/ boiling) / °C

Crucible

Observations after the measurement

36362

16.25

25

500

-

-

Aluminium with a hole

Test item optically unchanged

36366

16.69

25

500

-

-

Aluminium with a hole

Test item optically unchanged

The test item had no boiling point below 500 °C.

Executive summary:

The test item had no boiling point below 500 °C.

Description of key information

The test item had no boiling point below 500 °C.

Key value for chemical safety assessment

Additional information