Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

4.1. Description of first aid measures.
EYES: Remove contact lenses, if present. Wash immediately with plenty of water for at least 15 minutes, opening the eyelids fully. If problem
persists, seek medical advice.
SKIN: Remove contaminated clothing. Wash immediately with plenty of water. If irritation persists, get medical advice/attention. Wash
contaminated clothing before using it again.
INHALATION: Remove to open air. In the event of breathing difficulties, get medical advice/attention immediately.
INGESTION: Get medical advice/attention. Induce vomiting only if indicated by the doctor. Never give anything by mouth to an unconscious
person, unless authorised by a doctor.
4.2. Most important symptoms and effects, both acute and delayed.
For symptoms and effects caused by the contained substances, see chap. 11.
4.3. Indication of any immediate medical attention and special treatment needed.
Information not available.

Fire-fighting measures

5.1. Extinguishing media.
SUITABLE EXTINGUISHING EQUIPMENT
The extinguishing equipment should be of the conventional kind: carbon dioxide, foam, powder and water spray.
UNSUITABLE EXTINGUISHING EQUIPMENT
None in particular.
5.2. Special hazards arising from the substance or mixture.
HAZARDS CAUSED BY EXPOSURE IN THE EVENT OF FIRE
Do not breathe combustion products. The product is combustible and, when the powder is released into the air in sufficient concentrations and
in the presence of a source of ignition, it can create explosive mixtures with air. Fires may start or get worse by leakage of the solid product
from the container, when it reaches high temperatures or through contact with sources of ignition.
5.3. Advice for firefighters.
GENERAL INFORMATION
Use jets of water to cool the containers to prevent product decomposition and the development of substances potentially hazardous for health.
Always wear full fire prevention gear. Collect extinguishing water to prevent it from draining into the sewer system. Dispose of contaminated
water used for extinction and the remains of the fire according to applicable regulations.
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE-FIGHTERS
Normal fire fighting clothing i.e. fire kit (BS EN 469), gloves (BS EN 659) and boots (HO specification A29 and A30) in combination with
self-contained open circuit positive pressure compressed air breathing apparatus (BS EN 137).

Accidental release measures

6.1. Personal precautions, protective equipment and emergency procedures.
Use breathing equipment if fumes or powders are released into the air. These indications apply for both processing staff and those involved in
emergency procedures.
6.2. Environmental precautions.
The product must not penetrate into the sewer system or come into contact with surface water or ground water.
6.3. Methods and material for containment and cleaning up.
Confine using earth or inert material. Collect as much material as poss ble and eliminate the rest using jets of water. Contaminated material
should be disposed of in compliance with the provisions set forth in point 13.
6.4. Reference to other sections.
Any information on personal protection and disposal is given in sections 8 and 13.

Handling and storage

7.1. Precautions for safe handling.
Before handling the product, consult all the other sections of this material safety data sheet. Avoid leakage of the product into the
environment. Do not eat, drink or smoke during use.
7.2. Conditions for safe storage, including any incompatibilities.
Keep the product in clearly labelled containers. Keep containers away from any incompatible materials, see section 10 for details.
7.3. Specific end use(s).
Information not available.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not applicable
Shippingopen allclose all
Labels:
Not applicable
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not applicable
Shippingopen allclose all
Labels:
Not applicable
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not applicable
Shipping information
Proper shipping name and description:
Not applicable
Chemical name:
Not applicable
Labels:
Not applicable
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not applicable
Shipping information
Proper shipping name and description:
Not applicable
Chemical name:
Not applicable
Labels:
Not applicable
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

The substance is a trasported Intermediate use under SCC.

8.1. Control parameters.
During the risk assessment process, it is essential to take into consideration the ACGIH occupational exposure levels for inert particulate
otherwise classified (PNOC respirable fraction: 3 mg/m3; PNOC inhalable fraction: 10 mg/m3). For values above these limits, use a P type
filter, whose class (1, 2 or 3) must be chosen according to the outcome of risk assessment.
8.2. Exposure controls.
Comply with the safety measures usually applied when handling chemical substances.
HAND PROTECTION
None required.
SKIN PROTECTION
None required.
EYE PROTECTION
None required.
RESPIRATORY PROTECTION
Use a type P filtering facemask (see standard EN 149) or equivalent device, whose class (1, 2 or 3) and effective need, must be defined
according to the outcome of risk assessment.
ENVIRONMENTAL EXPOSURE CONTROLS.
The emissions generated by manufacturing processes, including those generated by ventilation equipment, should be checked to ensure
compliance with environmental standards.

Stability and reactivity

10.1. Reactivity.
There are no particular risks of reaction with other substances in normal conditions of use.
10.2. Chemical stability.
The product is stable in normal conditions of use and storage.
10.3. Possibility of hazardous reactions.
No hazardous reactions are foreseeable in normal conditions of use and storage.
10.4. Conditions to avoid.
None in particular. However the usual precautions used for chemical products should be respected.
10.5. Incompatible materials.
Information not available.
10.6. Hazardous decomposition products.
Information not available.

Disposal considerations

13.1. Waste treatment methods.
Reuse, when possible. Neat product residues should be considered special non-hazardous waste.
Disposal must be performed through an authorised waste management firm, in compliance with national and local regulations.
Solid residues may be suitable for disposal in an authorised landfill site.
CONTAMINATED PACKAGING
Contaminated packaging must be recovered or disposed of in compliance with national waste management regulations.