Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Frischluftzufuhr




"ENGLISH"


Ensure fresh air
Emergency measure - Eyes: Mit viel Wasser ausspülen; bei anhaltender Reizung Arzt
hinzuziehen.



"ENGLISH"


Rinse with a lot of water, consult a ophthalmologist if
irritation persists
Emergency measure - Skin: Keine besonderen Maßnahmen erforderlich.

"ENGLISH"


No special measurments necessary
Emergency measure - Ingestion: Bei Unwohlsein ärztlichen Rat einholen.




"ENGLISH"


Consult a physician in the case of indisposition

Fire-fighting measures

Recommended extinguishing agent: Löschpulver, Schaum, Wasser, Kohlendioxid, Sand

"ENGLISH"


extinguishing agents, foam, water, carbon dioxide, sand

Product arising from burning: Kohlendioxid, Kohlenmonoxid, Siliciumdioxid, Wasser

"ENGLISH"

CO2, CO, SiO2, H2O

Product determined by test: N

Protective equipment: Übliche Brandschutzausrüstung mit umluftunabhängigem
Atemschutzgerät




"ENGLISH"


The usual fire protection equipment with self-contained
respirator must be used.

Accidental release measures

Emergency measures in case of spillage: Mechanisch aufnehmen und ordnungsgemäß entsorgen.
Abfallbehälter sind zu kennzeichnen.





"ENGLISH"


Take up mechanically and dispose of in accordance with the
regulations. Waste containers must be labelled

Handling and storage

Handling: Die beim Umgang mit Chemikalien üblichen Vorsichtsmaßnahmen
sind zu beachten. Der allgemeine Staubgrenzwert sollte zudem
deutlich unterschritten werden, um sog. "Overloadphänomene"
(Überforderung der Lungenselbstreinigung beim Einatmen
unlöslicher Stäube) zu vermeiden. Folglich sollte durch die
Anwendung von geeigneten Arbeitsverfahren die Entwicklung
von Staub vermieden werden. Alternativ sollte möglicher
Staub unmittelbar am Entstehungsort abgesaugt werden.
Reichen die o.g. Maßnahmen nicht aus, wird das Tragen von
Atemschutz empfohlen.



"ENGLISH"


The precautionary measures usually taken when handling
chemicals must be observed. In addition, dust values

should remain clearly below the general dust limit value in
order to avoid so-called "overload phenomena" (excessive
demands being made on the clearance mechanism of the lungs
in the case of the inhalation of insoluble dusts).
Consequently, the formation of dust should be avoided by
using suitable working processes. Alternatively, any dust
which may form should be extracted directly at the point of
origin. If the above-mentioned measures are insufficient,
the wearing of respiratory protection is recommended.

Storage: Trockene Lagerung in fest geschlossenen Behältern.




"ENGLISH"


store dry in tightly closed containers.

Packaging of the substance and or preparation: Kombihobbock (30 l)

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Behälter gegen Herabfallen sichern und vorschriftsmäßig
kennzeichnen.





"ENGLISH"


Secure containers against falling, label properly
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Keine




"ENGLISH"


none

Chemical reaction with water: Keine Reaktion



"ENGLISH"


no reaction

Dust explosion: Test wurde durchgeführt, Bericht liegt jedoch noch nicht vor


"ENGLISH"


Test was conducted but the report is not yet available.

Dust explosion determined by test: Y

Disposal considerations

Industry - Possibility of recovery/recycling: Keine bekannt



"ENGLISH"


none known

Industry - Possibility of neutralisation: Nicht bekannt



"ENGLISH"


not known

Industry - Possibility of destruction: controlled discharge: Nicht empfohlen

"ENGLISH"


not recommended

Industry - Possibility of destruction - incineration: Code: 661

Verbrennung in einer Anlage mit Rauchgaswäsche

"ENGLISH"

Code: 661

Incineration in a plant with flue gas scrubber

Industry - Possibility of destruction - water purification: Nicht empfohlen



"ENGLISH"


not recommended