Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Description of key information

Not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Flammability test on the test item was performed according to the Method A.10 Flammability (Solids), Directive 84/449/EEC.

Justification for classification or non-classification

According to the CLP Regulation (EC 1272/2008), flammable solids are classified in:
- category 1
Substances and mixtures other than metal powders: (a) wetted zone does not stop fire and (b) burning time < 45 seconds or burning rate > 2.2 mm/s
Metal powders burning time ≤ 5 minutes
- category 2
Substances and mixtures other than metal powders: (a) wetted zone stops the fire for at least 4 minutes and (b) burning time < 45 seconds or burning rate > 2.2 mm/s
Metal powders burning time > 5 minutes and ≤ 10 minutes.


 


Test item is not highly flammable in the sense of EU method method A.10 (Directive 84/449/EEC). Therefore, no classification applies.