First-aid measures

Following inhalation

Remove victim to fresh air. If not breathing, give artificial respiration, better not to mouth-to-mouth. If breathing is difficult, give oxygen. Consult medical personnel.

Following skin contact

Wash material off the skin with plenty of soap and water. If redness, itching or a burning sensation develops, get medical attention.

Following eye contact

Immediately flush with plenty of water for at least 15 minutes. If redness, itching or a burning sensation develops, have eyes examined and treated by medical personnel.

Following ingestion

Provided the patient is conscious, wash out mouth with water. Vomiting should only be induced under the direction of a physician or a poison control centre.

Fire-fighting measures

Suitable extinguishing media

Use extinguishing media appropriate, such as water spray, alcohol-resistant foam, dry chemical powder or carbon dioxide, for surrounding fire.

Unsuitable extinguishing media

Avoid high pressure media which could cause the formation of a potentially explosible dust.

Special hazards arising from the substance or mixture

Emit toxic fumes under fire conditions, such as carbon oxides, Nitrogen oxides (NOx);

If substance is an organic solid, fine dust dispersed in air in sufficient concentrations in the presence of an ignition source is a potential for a dust explosion hazard.

Advice for fire-fighters

Keep containers cool with water spray and on special protective equipment for firefighters, such as boots, overalls, gloves, eye and face protection and breathing apparatus.

Accidental release measures

Personal precautions, protective equipment and emergency procedures

For non-emergency personnel

a) the wearing of suitable protective equipment (including personal protective equipment referred to under Section 8 of the safety data sheet)to prevent any contamination of skin, eyes and personal clothing;

b) removal of ignitionsources, provision of sufficient ventilation, control of dust; and

c) Emergency procedures such as the need to evacuate the danger area or to consult an expert.

For emergency responders

Wear positive pressure self-contained breathing apparatus, wear anti - toxic, anti - static, wear chemical anti - penetration gloves.

Environmental precautions

Prevent entry to sewers and public waters.

Methods and material for containment and cleaning up

For containment

Contain solid spills with appropriate barriers and prevent migration and entry into sewers or streams.

For cleaning up

Clean up spills immediately and dispose of waste safely. Recover the product by vacuuming, shovelling or sweeping. Transfer spilled material to a suitable container for disposal. Contact competent authorities after a spill.

Handling and storage

Precautions for safe handling

a) Take measures to prevent the build-up of electrostatic charge.

b) Provide appropriate exhaust ventilation at places where dust is formed.

c) Not to eat, drink, smoke in work areas.

d) To wash hands after use.

e) To remove contaminated clothing and protective equipment before entering eating areas.

Conditions for safe storage, including any incompatibilities

Technical measures and storage conditions

a) Store away from incompatible substances.

b) Keep tightly closed and store in a dry place and well-ventilated place.

c) Recommended Temperature controlled NMT30℃ for storage.

d) Hygroscopic. Store under inert gas.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not applicable
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not applicable
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not applicable
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not applicable
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Appropriate engineering controls

a) Suitable eye/body wash equipment should be available in the vicinity of any potential exposure.

b) Ensure adequate ventilation, especially in confined areas.

c) Use explosion-proof electrical appliances, ventilation, lighting and other equipment.

d) Set up emergency evacuation routes and necessary evacuation zones.

Personal protective equipment

Eye / Face protection

Use equipment for eye/faceprotection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

a) Wear suitable protective clothing.

b) Handle with gloves.Gloves must be inspected prior to use. Use proper gloves removal technique (without touching glove`s outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.

c) The selected protective gloves have to satisfy the specifications of Regulation(EU 2016/425)and the standard EN 374 derived from it.

d) This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

Body protection

Choose body protection in relation to its type, to the concentration and amount of dangerous substance, and to the specific work-place,the type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Respiratory protection

Respiratory protection is not required. Where protection from nuisance levels of dusts are desired, use type N95(US)or type P1(EN143) dust masks.use respirators and components tested and approved under appropriate gpvernment standards such as NIOSH(US)or CEN(EU).

Control of environmental exposure

No special environmental precautions required.

Stability and reactivity

Reactivity

No data available.

Chemical stability

The substance is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Possibility of hazardous reactions

No data available.

Conditions to avoid

Direct sunlight, extremely high temperatures, hygroscopic and incompatible materials.

Incompatible materials

Strong acids, strong bases, strong oxidizers.

Hazardous decomposition products

Hazardous decomposition products formed under fire conditions.--Carbon monoxide, Carbon dioxide, Nitrogen oxides and others.

Disposal considerations

Waste treatment methods

a) Dispose of contents/container in accordance with local, regional, national, and international regulations. Avoid release to the environment.