Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
substances / mixtures which in contact with water emit flammable gases
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 June to 13 October 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.12 (Flammability (Contact with Water))
Version / remarks:
December 1992
Deviations:
no
GLP compliance:
yes
Key result
Test procedure:
other:
Max. rate of gas release:
0
Identity of evolved gas:
not applicable as no gas evolved
Remarks on result:
no reaction with water observed
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test substance is not flammable in contact with water.
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 June to 13 October 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
December 1992
Deviations:
no
GLP compliance:
yes
Key result
Test procedure:
burning time (test type not further specified)
Burning time:
0 s
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test substance is considered not highly flammable.

Description of key information

The test substance is considered not highly flammable and is not flammable in contact with water or air.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test substance did not ignite under the conditions of this study. Therefore the test substance is not considered to be highly flammable and is not classified.