Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1 June 1993 and 28 June 1993
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Version / remarks:
Method A14 of Commission Directive 92/ 69/ EEC (which constitutes Annex V of Council Di rective 67/ 548/ EEC).
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
No further details specified in the study report.
Key result
Parameter:
other: BAM FALL HAMMER TEST
Remarks on result:
other: No signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.
Key result
Parameter:
other: BAM FRICTION TEST
Remarks on result:
other: No signs of ignition or explosion .
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks:
2 mm
Remarks on result:
not thermal sensitive if heated under defined confinement
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks:
6 mm
Remarks on result:
not thermal sensitive if heated under defined confinement

BAM FALL HAMMER TEST

Test 1: No signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

Test 2: No signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

Test 3: No signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

Test 4: No signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

Test 5: No signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

Test 6: No signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

 

RESULT: Negative.

 

BAM FRICTION TEST

Test 1: No signs of ignition or explosion.

Test 2: No signs of ignition or explosion.

Test 3: No signs of ignition or explosion.

Test 4: No signs of ignition or explosion.

Test 5: No signs of ignition or explosion.

Test 6: No signs of ignition or explosion.

 

RESULT: Negative.

 

KOENEN STEEL TUBE TEST

2 mm Orifice Plate

Test

 

T1

T2

1

2

3

Tube recovered unchanged.

Tube recovered unchanged.

Tube recovered unchanged.

38

36

37

300

300

300

6 mm Orifice Plate

Test

 

T1

T2

1

2

3

Tube recovered unchanged.

Tube recovered unchanged.

Tube recovered unchanged.

59

55

59

300

300

300

Where:

T1 = time (in seconds) from application of the flame to a noticeable effect from the orifice

T2 = time (in seconds) from application of the flame to the recorded event (e.g. explosion) or as in these tests, to the end of the test with no record event.

 

RESULT: Negative

Interpretation of results:
GHS criteria not met
Conclusions:
JPR BLUE 100 has been determined not to have explosive properties.
Executive summary:

A number of hazardous physico-chemical properties of the compound JPR BLUE 100 (Lot Number 303001) have been determined at the request of the sponsor.

 

The Explosiveness study complied with Method A14 of Commission Directive 92/ 69/ EEC (which constitutes Annex V of Council Directive 67/ 548/ EEC).

 

JPR BLUE 100 has been determined not to have explosive properties.

Description of key information

JPR BLUE 100 has been determined not to have explosive properties.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

A number of hazardous physico-chemical properties of the compound JPR BLUE 100 (Lot Number 303001) have been determined at the request of the sponsor.

The Explosiveness study complied with Method A14 of Commission Directive 92/ 69/ EEC (which constitutes Annex V of Coucil Directive 67/ 548/ EEC).

JPR BLUE 100 has been determined not to have explosive properties.

Justification for classification or non-classification

JPR BLUE 100 has been determined not to have explosive properties, therefore, does not trigger any classification requirements under CLP regulations .