Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 D (Ready Biodegradability: Closed Bottle Test)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
1-hydroxyoctan-2-yl octadeca-9,12,15-trienoate; 2-hydroxyoctyl octadeca-9,12,15-trienoate; 2-hydroxyoctyl octadeca-9,12-dienoate; octane-1,2-diol
EC Number:
944-490-2
Molecular formula:
unknown
IUPAC Name:
1-hydroxyoctan-2-yl octadeca-9,12,15-trienoate; 2-hydroxyoctyl octadeca-9,12,15-trienoate; 2-hydroxyoctyl octadeca-9,12-dienoate; octane-1,2-diol
Test material form:
liquid

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic (adaptation not specified)
Details on inoculum:
Secondary effluent, microorganisms from a domestic waste water treatment plant. The secondary effluent used for this study was allowed to settle approximately for an hour, then the decanted effluent was aerated until use (not later than an hour).
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
2.2 mg/L
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
O2 consumption
Reference substance
Reference substance:
benzoic acid, sodium salt

Results and discussion

% Degradation
Key result
Parameter:
% degradation (O2 consumption)
Value:
63
Sampling time:
28 d
Details on results:
Under the test conditions the percentage biodegradation of Diolenique C8 reached a mean of 63.0 % after 28 days based on the COD of the test item.
According to the test guidelines the pass level for ready biodegradability, 60 % of ThOD/COD and this level has to be reached in a 10-day window within the 28-day period of the test. The value obtained in a 14-day window would also be acceptable in the used method, however test item was degraded to a mean of 46.0 % after 14 days, therefore the test item is considered not readily biodegradable.

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
not readily biodegradable
Conclusions:
The test item was not considered to have significant inhibitory effects on the secondary effluent microorganisms.
Based on the results of this study, the test item is considered not readily biodegradable.