Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-10-30 to 2018-04-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
16.9 min
Remarks on result:
other: The pile burned over a distance of 200 mm within 16 min 54 seconds

In the preliminary test, the pile burned over a distance of 200 mm within 16 min 54 s. Therefore, the performance of the main test was not necessary as the test item is not a readily combustible solid.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The flammability of the test item was determined according to UN N.1. During the preliminary screening test, the pile burned over a distance of 200 mm within 16 min 54 s. Therefore, no main test was necessary.
Executive summary:

The flammability of the test item was determined according to UN N.1. During the preliminary screening test, the pile burned over a distance of 200 mm within 16 min 54 s. Therefore, no main test was necessary. The test item is not a readily combustible solid in the sense of UN Manual of Tests and Criteria, Method N.1 and the test item is not a flammable solid according to 2.7 of the GHS (CLP) regulations.

Description of key information

The flammability of the test item was determined according to UN N.1. During the preliminary screening test, the pile burned over a distance of 200 mm within 16 min 54 s. Therefore, no main test was necessary. The test item is not a readily combustible solid in the sense of UN Manual of Tests and Criteria, Method N.1 and the test item is not a flammable solid according to 2.7 of the GHS (CLP) regulations.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification