Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
not specified
GLP compliance:
no
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
Pyridine-2,6-dicarboxylic acid
EC Number:
207-894-3
EC Name:
Pyridine-2,6-dicarboxylic acid
Cas Number:
499-83-2
Molecular formula:
C7H5NO4
IUPAC Name:
pyridine-2,6-dicarboxylic acid
Test material form:
solid: crystalline

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Key result
Type:
log Pow
Partition coefficient:
< 0.3
Temp.:
25 °C
pH:
ca. 1.8

Any other information on results incl. tables

Test ItemDipicolinic acid (DPA)

  Measurement Data

The retention times of the test item peak are presented in the following table:

Table6.2‑a      Retention Times (RT) Test Item

Measurement

RT

 

min.

Measurement 1

1.667

Measurement 2

1.667

Measurement 3

1.667

Mean

1.667

Standard deviation

0.000

 

  Calculated Values

The calculated values are presented in the following table:

Table6.2‑b     Capacity Factor, log Capacity Factor, log POWTest Item

Measurement

k

log k

log POW

Measurement 1

0.1905

-0.7200

-0.092

Measurement 2

0.1905

-0.7200

-0.092

Measurement 3

0.1905

-0.7200

-0.092

Mean

 

 

-0.092

Relative Standard deviation

 

 

0.000

 

log POWwas calculated from the capacity factor as follows:

 

log POW= (log k + 0.6751) / 0.486

Using the correlation log k / log POW, the log POWof the peak of test itemDipicolinic acid (DPA)was calculated as -0.092 ± 0.000 (mean ± standard deviation). Because the retention time of the test item lay in the dead time of the method, the calculated log POWlay outside the calibrated range. The log POWof the test itemDipicolinic acid (DPA)is stated as
< 0.3(log POWof 2-Butanone as reference item with the lowest log POW) therefore.

1.1.1   Validity

The validity criteria and results are presented in the following table:

Table6.3‑a      Validity Criteria and Results

Parameter

Criterion

Found

Assessment

Range (Max – Min. log POW)

< 0.1

0.000

valid

Value within Range of Reference Items

0.30 - 2.70

-0.092

not valid*

*Because the retention time of the test item lay in the dead time of the method, the calculated log POWlay outside the calibrated range. The log POWof the test item is stated as < 0.3 (log POWof 2-Butanone as reference item with the lowest log POW) therefore

Applicant's summary and conclusion

Conclusions:
The log POW of the test item Dipicolinic acid (DPA) is stated as <0.3.
Executive summary:

The study was performed using a HPLC with a C18 column. Six reference items with different retention times and thiourea for the determination of the dead time were used to produce a calibration curve, since retention time on hydrophobic columns and POWare correlated.
The test item is ionisable. The ionisation state of the test item was estimated using non GLP software ACD/I-Lab 2.0: At pH 1.8 the test item is estimated to be uncharged > 90%. Therefore the log POWof the test item was determined at pH 1.8.

One vial was filled with the reference item mix and one vial with the test item solution. The vials were analysed using the HPLC with the program described below. First one injection from the solvent blank methanol/30 mM phosphate buffer 65/35 (v/v), pH 1.8 was made. Then three injections were measured from the reference item mix, three injections from the test item and again three injections from the reference item mix.

For each reference item, the capacity factor k was calculated from the retention time of thiourea and the retention time of the respective reference item.

A calibration function (log k versus log POW, linear fit) was determined using the literature values for POWof the reference items and the retention times in the six determinations.

The correlation log k/log POWis good: the coefficient of determination r2was calculated with 0.9601. This value was considered as sufficiently high to use the calibration function for the determination of the log POWof the test itemDipicolinic acid (DPA).

Using the correlation log k / log POW, the log POWof the test item peak ofDipicolinic acid (DPA)was calculated as -0.092 ± 0.000 (mean ± standard deviation). Because the retention time of the test item lay in the dead time of the method, the calculated log POWlay outside the calibrated range.

The log POWof the test itemDipicolinic acid (DPA)is stated as< 0.3
(log POWof 2-Butanone as reference item with the lowest log POW) therefore.