Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From October 22, 2015 to October 26, 2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

In preliminary screening test, Everlan SL53 does not ignite for a maximum 2 minutes.

Interpretation of results:
GHS criteria not met
Conclusions:
According to EU A.10 test method, Everlan SL53 is not classified as flammable solids. Therefore, Everlan SL53 was not met GHS criteria.
Executive summary:

The flammability properties of Everlan SL53 was determined according to EC REGULATION No 440/2008 Annex A.10 Flammability (Solids). In preliminary screening test, the test result showed that Everlan SL53 does not ignite for a maximum 2 minutes. Therefore, Everlan SL53 is not classified as flammable solids.

Description of key information

Everlan SL53 is not classified as flammable solids (EC A.10).

Key value for chemical safety assessment

Flammability:
not classified

Additional information

In preliminary screening test, the test result showed that Everlan SL53 does not ignite for a maximum 2 minutes. Therefore, Everlan SL53 is not classified as flammable solids.

Justification for classification or non-classification