Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin irritation: in vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according EU/OECD guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 404 (Acute Dermal Irritation / Corrosion)
Version / remarks:
(2008)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
methyl 1-(3-chloropyridin-2-yl)-3-(hydroxymethyl)-1H-pyrazole-5-carboxylate
EC Number:
937-132-1
Cas Number:
960316-73-8
Molecular formula:
C11H10ClN3O3
IUPAC Name:
methyl 1-(3-chloropyridin-2-yl)-3-(hydroxymethyl)-1H-pyrazole-5-carboxylate

Test animals

Species:
rabbit
Strain:
New Zealand White

Test system

Type of coverage:
semiocclusive
Preparation of test site:
shaved
Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent no treatment
Duration of treatment / exposure:
4h
Observation period:
72h
Number of animals:
3

Results and discussion

In vivo

Resultsopen allclose all
Irritation parameter:
erythema score
Basis:
mean
Time point:
other: 24-72 hours
Score:
0
Max. score:
4
Irritation parameter:
edema score
Basis:
mean
Time point:
other: 24-72 hours
Score:
0
Max. score:
4

Applicant's summary and conclusion

Interpretation of results:
not irritating
Remarks:
Migrated information Criteria used for interpretation of results: EU
Conclusions:
No clinical signs of systemic toxicity were observed in the animals during the study and no mortality occurred. The body weights of all rabbits were considered to be within the normal range of variability.The test material is a non-toxic after acute dermal administration and is therefore considered to be not irritating to the skin according to the Draize classification system.