Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
1982
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well-documented study report which meets basic scientific principles

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1982
Report date:
1982

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Internal procedure: I.I. Cummings and P.R. Michael, "Determination of the Aqueous Solubility of Hydrophobic compounds by a Saturator Column Technique," ES-82-M-8
Deviations:
no
GLP compliance:
no
Remarks:
No GLP statement, statement of QA is present
Type of method:
other: saturator column technique

Test material

Constituent 1
Reference substance name:
Terphenyl
EC Number:
247-477-3
EC Name:
Terphenyl
Cas Number:
26140-60-3
Molecular formula:
C18H14
IUPAC Name:
2-phenyl-1,1'-biphenyl; 3-phenyl-1,1'-biphenyl; 4-phenyl-1,1'-biphenyl
Constituent 2
Reference substance name:
MCS 1980
IUPAC Name:
MCS 1980
Details on test material:
- Name of test material (as cited in study report): MCS 1980
- Lot/batch No.:1950221

Results and discussion

Water solubility
Water solubility:
ca. 0.151 mg/L
Temp.:
25 °C
Remarks on result:
other: Relative St Dev 8.6%
Details on results:
Four aqueous solubility runs are summerized:
flow rate through saturator column (ml/min): 1, 2.5, 1, 2.5
total volume collected (ml): 5, 5, 10, 10
measured concentration in saturated solution (ppb): 147, 134, 160, 162 Mean: 151 St Dev: 8.6%
temperature: (25 ± 2)°C
Blank runs without the saturator column produced no measurable interferences.

Any other information on results incl. tables

Table 1: Data from MCS 1980 aqueous solubility experiments at ambient temperature (25 ± 2°C)

Flow rate through saturator column

(ml/min)

Total volume collected

(ml)

Measured concentration in saturated solution

(mg/l)

1

5

0.147

2.5

5

0.134

1

10

0.160

2.5

10

0.162

Mean

151

% Relative Standard Deviation

8.6%

Applicant's summary and conclusion

Conclusions:
Interpretation of results (migrated information): slightly soluble (0.1-100 mg/L)
The aqueous solubility of MCS 1980 was determined to be 0.151 mg/l with a standard deviation of 0.13 mg/l.
Executive summary:

The aqueous solubility of MCS 1980 was measured by the saturator column technique according to an internal procedure. The mean measured concentration in saturated solution at ambient temperature was determined to be 0.151 mg/l with a standard deviation of 0.13 mg/l