Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Phototransformation in air

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
phototransformation in air
Type of information:
(Q)SAR
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Meets generally accepted scientific standards, well document and acceptable for assessment
Justification for type of information:
QSAR prediction: migrated from IUCLID 5.6
Principles of method if other than guideline:
AOPWIN v1.92 and v1.91 accessed via Epiweb v 4.10
Estimation method (if used):
PHOTOCHEMICAL REACTION WITH OH RADICALS
- Computer programme: AOPWIN v1.92 and v1.91 accessed via Epiweb v 4.10

Physical property inputs:
- Log Kow (octanol-water): 4.60
- Boiling Point (deg C): 235.00
- Melting Point (deg C): -20.00
- Vapour Pressure (mm Hg): 0.098
- Water solubility (mg/L): 7.81

Half-lives (hr), (based upon Biowin (ultimate) and Aopwin):

Air: 5.55

Conclusions:
The phototransformation half-life of the test item in air was calculated as 5.545 hours using EPIsuite-AOPWIN.

Description of key information

The phototransformation half-life of the test item in air was calculated as 5.545 hours using EPIsuite-AOPWIN.

Key value for chemical safety assessment

Half-life in air:
5.55 h

Additional information