Administrative data

First-aid measures

Emergency measure - Inhalation: Remove victim from exposure area. Consult physician.

Emergency measure - Eyes: Flush eyes with running water for 15 minutes, while keeping

the eyelids wide open and consult physician.

Emergency measure - Skin: Wash the skin with water and soap.

Emergency measure - Ingestion: Rinse mouth with fresh water and consult physician.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, powder, foam, water spray.

Product arising from burning: Hydrogenchloride, Carbon an dnitrogen oxides.

Product determined by test: N

Protective equipment: Self-contained breathing apparatus. Special protective

equipment for fire fighters.

Accidental release measures

Emergency measures in case of spillage: Collect th eproduct and dispose of as chemical waste. Avoid

to discharge into the sewer.

Handling and storage

Handling: Local ventilation and/or respiratory protection (P2 dust

mask).

Protective gloves and clothing suitable for the handling of

chemicals. Safety goggles obligatory. Avoid discharge into

the sewer.

Storage: Keep in closed packaging, dry and at ambient temperature.

Packaging of the substance and or preparation: Packiging in polyethylene bags in plastic drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Free, no special labelling required.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: none

Chemical reaction with water: none

Dust explosion: not known

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Not applicable, substance is used as raw material in

chemical reaction.

Industry - Possibility of neutralisation: Not applicable.

Industry - Possibility of destruction - incineration: Approved incineration for chemical waste.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.