Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO 13736 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Abel apparatus
Key result
Flash point:
57.6 °C
Atm. press.:
972.6 hPa

OBSERVATIONS - 








































Method Details



Observations



Type of method




  • Closed cup



 



Flash point apparatus




  • Abel’s flash pt apparatus

  • Pensky-Martens flash point apparatus


Abel's flash point apparatus

Quantity of chemical used



g/mL



5 mL



Ignition source



Gas lighter/flame



gas lighter



Atmospheric pressure



hPa



972.6



mean flash point



°C



57.6


Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The flash point determination of test chemical was done . The method is closed cup method using Abel's Flash Point Apparatus. The flashpoint of the test chemical was determined to be 57.6°C at 972.6 hPa
Executive summary:
A study was performed to determine the flash point of test chemical  at atmospheric pressure.

The study was conducted in accordance with ISO 13736:2013 for Flash Point by Abel’s Closed Cup method.

The mean flash point of test chemical  was determined to be 57.6 °C at 972.6 hPa .

Description of key information

The flash point determination of test chemical was done . The method is closed cup method using Abel's Flash Point Apparatus. The flashpoint of the test chemical was determined to be 57.6°C at 972.6 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
57.6 °C

Additional information

A study was performed to determine the flash point of test chemical  at atmospheric pressure.

The study was conducted in accordance with ISO 13736:2013 for Flash Point by Abel’s Closed Cup method.

The mean flash point of test chemical  was determined to be 57.6 °C at 972.6 hPa .