Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the flash point is only relevant to liquids and low melting point solids
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 - 13 November 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch number of test material: Lot No. 30029
- Expiration date of the lot/batch: 3 May 2020
- Purity: 92.5 w%
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: Test substance metled in contact with the flame and did not ignite
Interpretation of results:
not classified based on GHS criteria
Conclusions:
Aryloxyacrylate was observed to be non-flammable in the preliminary test according to EC A.10; thus, it was not necessary to proceed with the full burning rate test.
Executive summary:

The flammability of aryloxyacrylate was evaluated according to EU method A.10. The sample of aryloxyacrylate melted in contact with flame and did not ignite, and showed no flame propagation during the preliminary test, thus the chemical is classified as not highly flammable. The test was conducted according to EU guidance and was GLP compliant; therefore the results are considered reliable without restriction.