Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Cleveland open cup tester
Key result
Flash point:
268 °C
Atm. press.:
101.2 kPa
Conclusions:
Flash point: 268°C (at 101.2 kPa barometric pressure)
Executive summary:

The determination of the flash point was performed in accordance with EU Method A.9. The flash point was measured with a Cleveland open cup tester. During the test, the ambient temperature was 15.0°C, the barometric pressure was 101.2 kPa. Based on the test results, the flash point is 268°C.

Description of key information

EU Method A.9

Key value for chemical safety assessment

Flash point at 101 325 Pa:
268 °C

Additional information

Cleveland open cup