Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
9 February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D2879 - 97 (2007) Standard Test Method for Vapour Pressure-Temperature Relation ship and Initial Decomposition Temperature of Liquids by Isoteniscope.
Deviations:
yes
Remarks:
A digital electronic pressure gauge and not a mercury manometer (as stipulated in ASTM D2879 - 97 2007) was used for pressure measurement.
GLP compliance:
no
Type of method:
isoteniscope
Key result
Temp.:
20 °C
Vapour pressure:
< 0.75 mm Hg

 

Vapour Pressure at 20°C/

mm Hg

Run 1

< 0.75

Run 2

< 0.75

Run 3

< 0.75

Average

< 0.75

Conclusions:
A vapour pressure < 0.75 mmHg at 20°C was determined for 2-Propenoic acid, 2-methyl-, tetracosyl ester(branched).
Executive summary:

The ASTM D2879 - 97 Standard Test Method for Vapour Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope was followed to determine the vapour pressure of test substance 2-Propenoic acid, 2-methyl-, tetracosyl ester(branched). The test substance was determined to have a vapour pressure < 0.75 mmHg at 20°C based on three runs.

Description of key information

The ASTM D2879 - 97 Standard Test Method for Vapour Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope was followed to determine the vapour pressure of test substance 2-Propenoic acid, 2-methyl-, tetracosyl ester(branched). The test substance was determined to have a vapour pressure < 0.75 mmHg at 20°C based on three runs. This is equivalent to a vapour pressure < 100 Pa at 20°C.

Key value for chemical safety assessment

Vapour pressure:
100 Pa
at the temperature of:
20 °C

Additional information