Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 November 2017 to 21 January 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
counted distribution
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: CCI Corp. / Bx 20170320
- Expiration date of the lot/batch: 19 March 2018
- Purity test date: 20 march 2017

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: stored at room temperature with no direct exposure to sunlight.
- Stability under test conditions: stable
- Solubility and stability of the test substance in the solvent/vehicle:
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium:

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing:
- Preliminary purification step (if any):
- Final dilution of a dissolved solid, stock liquid or gel:
- Final preparation of a solid:

FORM AS APPLIED IN THE TEST (if different from that of starting material)

TYPE OF BIOCIDE/PESTICIDE FORMULATION (if applicable)

OTHER SPECIFICS:
Key result
Percentile:
other: Mean particle size distribution range
Mean:
>= 15.3 - <= 246.1 µm
Remarks on result:
other: No S.D. available
Percentile:
D90
Mean:
94.9 µm
Remarks on result:
other: No S.D. available
Key result
Percentile:
D50
Mean:
41.4 µm
Remarks on result:
other: No S.D. available
Percentile:
D10
Mean:
15.3 µm
Remarks on result:
other: No S.D. available
Conclusions:
The D50 was found to be 41.4 µm.

Description of key information

The D50 was found to be 41.4 µm. This means 50% are smaller than 41.4 µm

Additional information