Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 26-02-2018 to 29-03-2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: European Pharmacopoeia
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
buoyancy method - hydrostatic balance

Test material

Constituent 1
Chemical structure
Reference substance name:
(2-aminoethoxy)[(2R)-2,3-dihydroxypropoxy]phosphinic acid hydrate
EC Number:
609-192-6
Cas Number:
35907-34-7
Molecular formula:
C5H14NO6P.H2O
IUPAC Name:
(2-aminoethoxy)[(2R)-2,3-dihydroxypropoxy]phosphinic acid hydrate
Test material form:
solid: particulate/powder

Results and discussion

Density
Key result
Type:
relative density
Density:
ca. 0.81 g/cm³
Temp.:
25 °C

Applicant's summary and conclusion

Conclusions:
The relative density is 0.81 g/mL