Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22 June 2016 to 14 October 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
European Community (EC), EC no. 761/2009, Part A: Methods for the Determination of Physico-Chemical Properties, Guideline A.4: “Vapour Pressure", Official Journal of the European Union no. L220, August 24, 2009.
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
Organization for Economic Co-operation and Development (OECD), OECD Guidelines for the Testing of Chemicals no.104: "Vapour Pressure", March 23, 2006.
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Version / remarks:
United States Environmental Protection Agency (EPA), Product Properties Test Guidelines no. OPPTS 830.7950: "Vapor pressure", August 1996.
Deviations:
no
GLP compliance:
yes
Type of method:
effusion method: isothermal thermogravimetry
Specific details on test material used for the study:
Batch: RC-1045Study specific test item informationPurity/composition correction factor: No correction factor requiredChemical name (IUPAC), synonym or trade name: Amides, tallow, N,N-bis(2-hydroxypropyl)CAS Number: 1454803-04-3Test item handling: No specific handling conditions required
Key result
Temp.:
20 °C
Vapour pressure:
0 Pa
Key result
Temp.:
20 °C
Vapour pressure:
0 mm Hg
Key result
Temp.:
25 °C
Vapour pressure:
0 Pa
Key result
Temp.:
25 °C
Vapour pressure:
0 mm Hg

Results of the isothermal TGA analysis

Temperature

[°C]

Weight loss

[μg/min]

νT

[g/cm2/h]

LogνT

Log PT

PT

[Pa]

160

 

 

170

  

180

 

 

190

 

 

5.653

6.733

 

9.241

11.29

 

18.08

20.84

 

36.35

38.49

6.75 x 10-4

8.04 x 10-4

 

1.10 x 10-3

1.34 x 10-3

 

2.16 x 10-3

2.49 x 10-3

 

4.34 x 10-3

4.59 x 10-3

-3.17

-3.09

 

-2.96

-2.87 

-2.67

-2.60

 

-2.36

-2.34

0.93

1.02

 

1.18

1.27

1.51

1.58

 

1.86

1.88

8.6

10

 

15

19 

32

38

 

72

77

 

Vapour pressure of the test item

Temperature

[°C]

Log PT

PT

[Pa]

PT

[mm Hg]

20

 

25

-5.68

 

-5.34

2.1 x 10-6

 

4.6 x 10-6

1.6 x 10-8

 

3.5 c 10-8

 

Conclusions:
The vapour pressure of the test item at 20°C (293K) and 25°C (298K) was:2.1e-6 Pa (1.6e-8 mm Hg) at 20°C4.6e-6 Pa (3.5e-8 mm Hg) at 25°C
Executive summary:

The purpose of the study was to determine the physico-chemical properties for MLA-3202.

 

The vapour pressure of the test item (PT) was determined by the isothermal thermogravimetric effusion method, in accordance with the following guidelines:

European Community (EC), EC no. 761/2009, Part A: Methods for the Determination of Physico-Chemical Properties, Guideline A.4: “Vapour Pressure", Official Journal of the European Union no. L220, August 24, 2009.

Organization for Economic Co-operation and Development (OECD), OECD Guidelines for the Testing of Chemicals no.104: "Vapour Pressure", March 23, 2006.

United States Environmental Protection Agency (EPA), Product Properties Test Guidelines no. OPPTS 830.7950: "Vapor pressure", August 1996.

 

The isothermal TGA effusion method was applied for the determination of the vapour pressure of MLA-3202.

 

The vapour pressure of the test item at 20°C (293K) and 25°C (298K) was:

2.1e-6 Pa (1.6e-8 mm Hg) at 20°C

4.6e-6 Pa (3.5e-8 mm Hg) at 25°C

Description of key information

Key value determined in a GLP accredited laboratory study by the isothermal thermogravimetric effusion method, in accordance with EU Method A.4,OECD Guideline.104and US EPA Procedure OPPTS 830.7950.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information

The isothermal TGA effusion method was applied for the determination of the vapour pressure of MLA-3202.

 

The vapour pressure of the test item at 20°C (293K) and 25°C (298K) was:

2.1e-6 Pa (1.6e-8 mm Hg) at 20°C