Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-12-22 – 2016-12-22
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Principles of method if other than guideline:
The flow of test item under gravity through a capillary using Redwood Viscometer No. 1
GLP compliance:
not specified
Type of method:
capillary viscometer (static)
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
16.79
Remarks on result:
other: Kinematic viscosity (experimental)
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
12.75
Remarks on result:
other: Kinematic viscosity (experimental)
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
17.89
Remarks on result:
other: Dynamic viscosity (calculated)
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
13.59
Remarks on result:
other: Dynamic viscosity (calculated)
Conclusions:
Kinematic viscosity (experimental) of test item at 20°C and 40°C is 16.79mm²/secand 12.75mm²/s,respectively. Dynamic viscosity (calculated) of test item at 20°C and 40°C is 17.89 mPa.Sand 13.59mPa.S, respectively.
Executive summary:

Kinematic viscosity (experimental) of test item at 20°C and 40°C is 16.79mm²/secand 12.75mm²/s,respectively. Dynamic viscosity (calculated) of test item at 20°C and 40°C is 17.89mPa.Sand 13.59mPa.S, respectively.

Description of key information

Kinematic viscosity (experimental) of test item at 20°C and 40°C is 16.79mm²/secand 12.75mm²/s,respectively. Dynamic viscosity (calculated) of test item at 20°C and 40°C is 17.89mPa.Sand 13.59mPa.S, respectively.

Key value for chemical safety assessment

Viscosity:
16.79 mm²/s (static)
at the temperature of:
20 °C

Additional information

Kinematic viscosity (experimental) of test item at 20°C and 40°C is 16.79mm²/secand 12.75mm²/s,respectively. Dynamic viscosity (calculated) of test item at 20°C and 40°C is 17.89mPa.Sand 13.59mPa.S, respectively.