Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 405 (Acute Eye Irritation / Corrosion)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 870.2400 (Acute Eye Irritation)
Qualifier:
according to guideline
Guideline:
EU Method B.5 (Acute Toxicity: Eye Irritation / Corrosion)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Ethanone, 2-​chloro-​1-​(3-​chloro-​4-​hydroxyphenyl)​-
Cas Number:
39066-18-7
Molecular formula:
C8 H6 Cl2 O2
IUPAC Name:
Ethanone, 2-​chloro-​1-​(3-​chloro-​4-​hydroxyphenyl)​-
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Test animals / tissue source

Species:
rabbit
Strain:
New Zealand White

Test system

Vehicle:
unchanged (no vehicle)
Controls:
not required
Amount / concentration applied:
0.1 g
Observation period (in vivo):
72 hours
Number of animals or in vitro replicates:
1

Results and discussion

In vivo

Resultsopen allclose all
Irritation parameter:
cornea opacity score
Basis:
animal #1
Time point:
other: mean value 24-48-72 hours
Score:
0.33
Max. score:
4
Reversibility:
not reversible
Remarks:
whitin 21 days post instillation
Remarks on result:
positive indication of irritation
Irritation parameter:
iris score
Basis:
animal #1
Time point:
other: mean value 24-48-72 hours
Score:
1
Max. score:
2
Reversibility:
not reversible
Remarks:
whitin 21 days post instillation
Remarks on result:
positive indication of irritation
Irritation parameter:
conjunctivae score
Remarks:
redness
Basis:
animal #1
Time point:
other: mean value 24-48-72 hours
Score:
3
Max. score:
3
Reversibility:
not reversible
Remarks:
whitin 21 days post instillation
Remarks on result:
positive indication of irritation
Irritation parameter:
chemosis score
Basis:
animal #1
Time point:
other: mean value 24-48-72 hours
Score:
3
Max. score:
4
Reversibility:
not reversible
Remarks:
whitin 21 days post instillation
Remarks on result:
positive indication of irritation
Irritation parameter:
conjunctivae score
Remarks:
discharge
Basis:
animal #1
Time point:
other: mean value 24-48-72 hours
Score:
2
Max. score:
3
Reversibility:
not reversible
Remarks:
whitin 21 days post instillation
Remarks on result:
positive indication of irritation
Irritant / corrosive response data:
the product showed irritation effects

Applicant's summary and conclusion

Interpretation of results:
irritating
Remarks:
Migrated information Criteria used for interpretation of results: EU
Conclusions:
The product produce severe irritation with corrosive effects