Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
May 11, 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7100 (Viscosity)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: Method ASTM D 445-06
Deviations:
no
GLP compliance:
no
Other quality assurance:
other: Please see 'remarks'
Remarks:
According to ASTM D 445-06EPA OPPTS 830.7100, OECD 114, which describes a procedure designed to evaluate this endpoint. The testing laboratory was accredited to ISO 9000 series standards and results obtained reviewed for reliability and validity.
Type of method:
capillary viscometer (static)
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
2.57
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.71
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Principles of method if other than guideline:
handbook data, no information is given on test method
GLP compliance:
not specified
Type of method:
other: not specified
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
2.9

Description of key information

kinematic viscosity:

2.57 mm²/s at 20 °C
1.71 mm²/s at 40 °C

(capillary viscometer, OECD 114)

Key value for chemical safety assessment

Viscosity:
2.57 mm²/s (static)
at the temperature of:
20 °C

Additional information

Handbook data stating a viscosity of 2.9 mPa*s at 20 °C are supporting.