Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study according to national/international standards
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D850-02
Deviations:
no
GLP compliance:
no
Type of method:
distillation method

Test material

Constituent 1
Reference substance name:
90640-86-1
Cas Number:
90640-86-1
IUPAC Name:
90640-86-1
Constituent 2
Reference substance name:
Distillates (coal tar), heavy oils
EC Number:
292-607-4
EC Name:
Distillates (coal tar), heavy oils
IUPAC Name:
292-607-4
Constituent 3
Reference substance name:
Distillates (coal tar), heavy oils
IUPAC Name:
Distillates (coal tar), heavy oils
Details on test material:
CCSG-composite sample No. 6, anthracene oil (B(a)P > 50 ppm), ATE-No. 10442

Results and discussion

Boiling point
Boiling pt.:
ca. 340 - ca. 400 °C
Atm. press.:
ca. 101 kPa
Decomposition:
no
Decomp. temp.:
> 400 °C
Remarks on result:
other: based on ASTM D850-02

Any other information on results incl. tables

Detailed results on composite sample:

[Note: The temperature range in which 10 to 90 % of the compound distills is considered as relevant boiling range,

based on the ASTM method]

Analysis (Distillation)

Analytical result (ASTM D850-02)

% Distillate

Temperature [°C]

0

298

5

321

10

339

20

354

30

372

40

386

50

399

60

70

80

90

95

  Analysis Unit  Analytical results (CEN TC 317)
< 230 °C  [%]  1.6 
231 - 271 °C  [%] 6.9   
271 - 360 °C  [%]  19.0 
361 - 435 °C  [%]  25.2 
436 - 500 °C  [%]  21.9 
> 500 °C  [%]  1.5 

Applicant's summary and conclusion

Conclusions:
-
Executive summary:

-