Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1999
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: Cleveland closed cup
Principles of method if other than guideline:
The flash point was measured on a Labline Flash Point instrument using the closed cup method. Typical sample loading range from 50 to 100 g. The temperature is increased during the experiment at approximately 8-10 ºC/min. The ignition source is an open flame.
GLP compliance:
not specified
Type of method:
closed cup

Test material

Constituent 1
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Flash point
Flash point:
ca. 155 °C
Atm. press.:
ca. 1 atm

Applicant's summary and conclusion

Conclusions:
flashpoint D-100 was determined to be 155°C