First-aid measures

Description of first aid measures

Inhalation: Move exposed person to fresh air. Keep person warm and at rest.If not breathing, if brasthing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained prsonnel. Get medical attention if symptoms occur. If unconscious, place i recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Ingestion: Wash out mouth with water. Move exposed person to fresh air. Keep person warm and at rest. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if symptoms occur. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Skin contact: Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Eye contact:Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media       : In case of fire, use water spray (fog), foam, dry chemical or CO2.

Unsuitable extinguishing media       : None known.

Special hazards arising from the substance or mixture

Hazards from the substance or mixture: No specific fire or explosion hazard.

Hazardous combustion products: Decompositionproducts may include the following materials:

carbon oxides

halogenated compounds

Advice for firefighters

Special prcautions for ire-fighters: promptly isolate the scene by removing all persons from the vicinity of the incedent if there is a fire. No action shall be taken invoving any personal risk or without suitable training.

Special protective equipment for fire-fighters:Fire-fighters should wear appropriate protective equipment and self-containes breathing apparatus(SCBA) with a full face-piece operated in positive pressure mode.

Accidental release measures

Personal precautions, protective equipment and emergency procederes:

No action shall be taken involving any personal risk or without suitable training. Keep unnecessary and unprotected personnel from entering. Provide adequate ventilation. Put on appropriate personal protective equipment. Hazard of slipping on split product.

Environmental prcautions: Avoid dispersal of split  material and run-off and contact with soil, waterways, drains, and sewers, Inform the relevant authorities if the product has caused environmetal pollution(sewers, waterways, soil or air).

Small spill: Move containers from spill area. Vacuum or sweep up material and place in a designated, labelled waste container. Dispose of via a licensed waste disposal contractor.

Large spill: Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Vacuum or sweep up material and place in a designated, labelled waste container. Dispose of via a licensed waste disposal contractor.

Handling and storage

Precautions for safe handling:  

Put on appropriate personal protective equipment . Eating, drinking and smoking should be prohibited in areas where

this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Do not ingest. Avoid contact with eyes, skin and clothing. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. The product is registered with strictly controlled conditions as defined in Article 17(3) or 18(4) of regulation (EC) no. 1907/2006 (REACH Regulation) and (flust therefore be handled as such. Refer to the industry guidance prepared by Concawe/Cefic/EFCG for advice on the confirmation of strictly controlled conditions.#

Conditions for safe storage , including  any incompatibilities:

Store in accordance with local regulations. Store in original       container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled containers. Use appropriate containment to avoid environmental contamination.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Current data on dangerous goods available only on request.
Shippingopen allclose all
Labels:
not applicable
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
not applicable
Shippingopen allclose all
Labels:
not applicable
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
not applicable
Shipping information
Proper shipping name and description:
not applicable
Chemical name:
not applicable
Labels:
-
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
not applicable
Shipping information
Proper shipping name and description:
not applicable
Chemical name:
not applicable
Labels:
not applicable
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure limit values: Not available.

Recommended monitoring procedures:

lf this product contains ingredients with exposure limits, personal, workplace atmosphere or biological monitoring may be required to determine the effectiveness of the ventilation or other control measures and/or the necessity to use respiratory protective equipment. Reference should be made to monitoring standards, such as the following: European Standard EN 689 (Workplace atmospheres - Guidance for the assessment of exposure by inhalation to chemical agents for comparison with limit values and measurement strategy) European Standard EN 14042 (Workplace atmospheres - Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents) European Standard EN 482 (Workplace atmospheres - General requirements for the performance of procedures for the measurement of chemical agents) Reference to national guidance documents for methods for the determination of hazardous substances will also be required.

Exposure controls

Risk management measures

Occupational exposure controls

Technicals measures:The substance shall be rigorously contained by technical means during its whole lifecycle including manufacture, purification, cleaning and maintenance of equipment, sampling, analysis, loading and unloading of equipment or vessels, waste disposal or purification and storage. Procedural and control technologies shall be used that minimise emission and any resulting exposure. In cases of accident and where waste is generated, procedural and/ or control technologies shall be used to minimise emissions and the resulting exposure during purification or cleaning and maintenance procedures.

Organisational measures: Only properly trained and authorised personnel shall handle the substance. In the case of cleaning and maintenance works, special procedures such as purging and washing shall be applied before the system is opened and entered.

Personal protection measures

Respiratory protection: : If exposure cannot be ruled out, e.g. during product transfer,

sampling or maintenance, a well-Fitting respiratory mask conforming to standards or well-fitting respiratory device conforming to standards must be worn. Respirator selection must be based an known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. Recommended: Dust-protection mask if there is a risk of dust formation.

Hand protection:  Chemical-resistant, impervious gloves complying with an approved

standard should be worn at all times when handling chemical products if product contact cannot be excluded. After contamination with product change the gloves immediately and dispose of them according to relevant national and local regulqations.

Recommended:(<1hour)polyvinyl chloride (PVC) or Rubber gloves.

Eye protection: Safetye eyewear complying withsän approved standard should be

used to avoid exposure to liquid splashes, mists, gases or dusts. Recommended: safety glasses with side-shields.

Skin protection: Wear protective clothing. Personal protective equipment for the body should be selected based an the task being performed and the risks involved and should be approved by a specialist before handling this product. Recommended: Wear protective clothing.

Hygiene measures: Wash hands, forearms and face thoroughly alter handling

chemical products, before eating, smoking and using the lavatory and at the end of the working period. Appropriate techniques should be used to remove potentially contaminated ciothing. Wash contaminated clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location.

Environmental exposure controls

Technical measures: Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection Legislation. In some cases, special waste water treatment, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Stability and reactivity

Reactivity:No specific test data related to reactivity available for this product or its ingredients

Chemical stability:  The product is stable.

Possibility of hazardous reactions:  Under normal conditions of storage and use, hazardous reactions will not occur.

Conditions to avoid: In the case of dusty organic products the possibility of a dust explosion should always be considered. No hazardous reactions when used as directed

Incompatible materials : No specific data.

Hazardous decomposition products:Under normal conditions of storage and use, hazardous decomposition products should not be produced

Disposal considerations

Waste treatment methods

Product

Methods of disposal: Examine possibilities for re-utilisation. Product residues and uncleaned empty containers should be packaged, sealed, labelled, and disposed of or recycled according to relevant national and local regulations. Where large quantities are concerned, consult the supplier. When uncleaned empty containers are passed on, the recipient must be warned of any possible hazard that may be caused by residues. For disposal within the EC, the appropriate code according to the European Waste List (EWL) should be used. lt is among the tasks of the polluter to assign the waste to waste codes specific to industrial sectors and processes according to the European Waste List (EWL).

Hazardous waste: Within the present knowledge of the supplier, this product is not regarded as hazardous waste, as defined by EU Directive 91/689/EEC.

Packaging

Methods of disposal: The generation of waste should be avoided or minimised wherever possible. Weste packaging should be recycled. Incineration or landfill should only be considered when recycling is not feasible.

Special precautions: This material and its container must be disposed of in a safe way. Empty containers or liners mal retain some product residues.

Avoid disposal of spill material and runoff and contact with soil, waterways, drains and sewers.