Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
January 24, 1984 thru September 28, 1984
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
documentation insufficient for assessment
Justification for type of information:
Weight of Evidence: The measured value is reported without adequate documentation to judge its reliability. However, when coupled with a read-across value and an estimated (QSAR) value, its reliability is enhanced.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1984
Report date:
1984

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: No guideline specified
Principles of method if other than guideline:
Not reported
GLP compliance:
no
Other quality assurance:
other: Eastman Kodak Quality Assurance Unit procedures
Type of method:
other: Not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
Lithium dihydrogen 5-sulphonatoisophthalate
EC Number:
256-275-4
EC Name:
Lithium dihydrogen 5-sulphonatoisophthalate
Cas Number:
46728-75-0
Molecular formula:
C8H6O7S.Li
IUPAC Name:
lithium dihydrogen 5-sulphonatoisophthalate
Test material form:
solid: particulate/powder
Details on test material:
- Moisture content: 6.5%
- Colour: Off-white

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
440 °C
Atm. press.:
1 atm
Decomposition:
no
Sublimation:
no

Applicant's summary and conclusion

Conclusions:
The measured melting point of the test substance was determined to be 440 deg C.
Executive summary:

In a non-GLP non-guideline study, the measured melting point of the test substance was determined to be 440 deg C.