Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 June 2020 - 09 June 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Contact with:
powdered cellulose
Key result
Sample tested:
test mixture as specified
Remarks:
(tested substance and cellulose in ratio weight 2:1)
Parameter:
preliminary test
Remarks on result:
other: NEGATIVE: The sample burned only on the top of the cone. The cone did not burn completely.
Key result
Sample tested:
reference mixture as specified
Remarks:
(mixture of barium nitrate(V) and cellulose in various weight ratios from 10% to 90%)
Parameter:
maximum burning rate
Result:
1.74 mm/s
Key result
Sample tested:
test mixture as specified
Remarks:
(mixture test substance with cellulose in various weight ratios from 10% to 90%)
Parameter:
burning rate
Remarks on result:
other: Mixtures of test item and cellulose did not burn completely or did not ignite.

Table 1. Results of the preliminary test

The mixture of test item and cellulose
in ratio weight 2:1

Burning time [s]

Remarks of reaction

Test-1

---

The sample burned only on the top of the cone. The cone did not burn completely. 

 

Result: NEGATIVE

Test-2

---

Test-3

---

The shortest burning time of mixture

of tested substance and cellulose – tp[s]

---

Burning time of standard mixture – tw[s]

30

Table 2: Results of determination of oxidizing properties for the reference mixture

Barium nitrate(V) [%]

10

20

30

40

50

60

70

80

90

Cellulose [%]

90

80

70

60

50

40

30

20

10

Burning time of the pile [s]

125

123

120

115

116

121

153

324

(20 mm/
55 s)*

Burning rate of the pile [mm/s]

1.60

1.62

1.67

1.74

1.72

1.65

1.31

0.62

 

Maximal burning rate of

the reference mixture pile[mm/s]

1.74

* the train does not burn completely

Table 3: Results of determination of oxidizing properties for test item

Test substance
(content in mixture) [%]

10

20

30

40

50

60

70

80

90

Cellulose (content in mixture) [%]

90

80

70

60

50

40

30

20

10

Burning time
of train [s]

(45 mm/ 65 s)*

(40 mm/ 55 s)*

278*

296*

320*

(35 mm/
45 s)*

NI

NI

NI

Burning rate
of the train [mm/s]

-

-

-

-

-

-

-

-

-

Maximal burning rate of the reference mixture train [mm/s]

1.74

* the train does not burn completely, NI - the train does not ignite

Interpretation of results:
other: Not classified (CLP Regulation EC no. 1272/2008)
Conclusions:
The tested material does not have oxidizing properties in accordance with test A.17 criteria.

Executive summary:

The study of determination of the oxidizing properties of the test substance was performed according to method A.17 Oxidizing properties for solids, following the principles of GLP. No vigorous reaction was observed in the preliminary test. The main test was performed with mixtures of test substance with cellulose in a range from 10 % to 90 % of cellulose content. Barium nitrate(V) was used as reference substance and reference mixtures were tested with the same contents of cellulose as those used for the test substance mixtures. The maximal burning rate of the reference mixtures was 1.74 mm/s whereas the test substance mixtures did not burn completely or did not ignite. Based on this result, it is concluded that the tested material does not have oxidizing properties.

Description of key information

Key study. Test performed according to EU method A.17. GLP study. The tested material does not have oxidizing properties.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification

Based on the available information, the tested material is not classified as oxidising solid according to CLP Regulation (EC) no.1272/2008.