Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 Mar 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Version / remarks:
(1981)
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
(2009)
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Remarks:
Hess. Ministerium für Umwelt, Klimaschutz, Landwirtschaft und Verbraucherschutz; Wiesbaden; Germany
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
(carboxymethyl)dimethyl-3-[(1-oxotetradecyl)amino]propylammonium hydroxide
EC Number:
261-684-6
EC Name:
(carboxymethyl)dimethyl-3-[(1-oxotetradecyl)amino]propylammonium hydroxide
Cas Number:
59272-84-3
Molecular formula:
C21H42N2O3
IUPAC Name:
(carboxymethyl)dimethyl-3-[(1-oxotetradecyl)amino]propylammonium hydroxide
Test material form:
solid: particulate/powder

Results and discussion

Particle sizeopen allclose all
Percentile:
D10
Mean:
3.1 µm
St. dev.:
0.04
Percentile:
D50
Mean:
12.4 µm
St. dev.:
0.29
Percentile:
D90
Mean:
52.9 µm
St. dev.:
0.98

Any other information on results incl. tables

Particle Size Distribution

Two test series of 3 measurements each were performed with the test item. The table below summarizes the particle size distribution results.

 

Test Series

D10 (µm)

Std dev (µm)

D50 (µm)

Std dev (µm)

D90 (µm)

Std dev (µm)

1

3.2

0.08

12.7

0.13

53.9

4.23

2

3.1

0.05

12.1

0.12

51.9

4.12

Average

3.1

0.04

12.4

0.29

52.9

0.98

Final Results

The fine fraction of the test item W-1108T has a median particle size of D50 = 12 µm, which was determined by laser diffraction measurement according to OECD Test Guideline 110 (1981) and ISO 13320 (2009).

Applicant's summary and conclusion