Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 October 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Assessed using appropriate methodology.
Qualifier:
according to guideline
Guideline:
other: particle size distribution determination
Deviations:
no
Principles of method if other than guideline:
Equipment: Rentsch AS 200 basic
Amplitude: 30
Sieving time: 20 minutes
Balance: Ohaus ARC-120 Adventure tara balance and SartoriusMSA324S0TRDU01 analytical balance
GLP compliance:
no
Remarks:
Conducted under non-GLP, but to appropriate methodology.
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Test substance name: Isophthalonitrile
Chemical name: 1,3-dicyanobenzene
CAS number: 626-17-5
EC number: 210-933-7
LOT number: JB1906150101
Purity: 99.8 % (w/w %)
Appearance: Off white solid flakes
Manufacture date: 15 June 2019
Expiry date: 15 June 2020
Storage condition: Room temperature (15-25oC. below 70 RH%), protected from humidity
Safety Precautions: Routine safety precautions for unknown materials (lab coat. mask. gloves and safety glasses) were applied to assure personnel health and safety.
Mass median aerodynamic diameter:
> 1 mm
No.:
#1
Size:
> 0 - < 63 µm
Distribution:
0.001 %
No.:
#2
Size:
> 63 - < 100 µm
Distribution:
0.003 %
No.:
#3
Size:
> 100 - < 200 µm
Distribution:
0.003 %
No.:
#4
Size:
> 200 - < 315 µm
Distribution:
0 %
No.:
#5
Size:
> 315 - < 630 µm
Distribution:
0 %
No.:
#6
Size:
> 630 - < 1 000 µm
Distribution:
0.002 %
No.:
#7
Size:
> 1 000 µm
Distribution:
0.991 %
Conclusions:
Particle size distribution showed that more than 99% of test item particles (by weight) are greater than 1 mm which equates to > 1000 microns.
Executive summary:

Particle size distribution showed that more than 99% of test item particles (by weight) are greater than 1 mm which equates to > 1000 microns.

Description of key information

Particle size distribution showed that more than 99% of test item particles (by weight) are greater than 1 mm which equates to > 1000 microns.

Additional information