Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
05 December 2017 - 25 April 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
Version / remarks:
2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: Council Regulation (EC) No. 440/2008 laying down test methods pursuant to Regulation (EC) No. 1907/2006 (REACH). B.40.bis. In vitro skin corrosion: human skin model test.
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: INVITTOX Protocol SkinEthic™ Skin Corrosivity Test
Version / remarks:
2012
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Disodium L-3-(4-hydroxyphenyl)alaninate hydrate
Molecular formula:
C9H9NNa2O3 • xH2O
IUPAC Name:
Disodium L-3-(4-hydroxyphenyl)alaninate hydrate
Test material form:
solid

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Justification for test system used:
The reconstructed human epidermis model in vitro method is an accepted in vitro method to replace animal testing. The human skin RHE™ model closely mimics the biochemical and physiological properties of the upper parts of the human skin, i.e the epidermis.
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: SkinEthic™ RHE-model RHE/S/17
- Tissue batch number: 16-RHE-130

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: room temperature (3 min or 1 h)

REMOVAL OF TEST MATERIAL AND CONTROLS
-Volume and number of washing steps: gently rinsing with a minimum volume of 20 mL DPBS using a pipette. Excess DPBS was removed by gently shaking the tissue inserts and blotting the bottom of the tissue inserts with blotting paper.
- Observable damage in the tissue due to washing: No

MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 1 mg/mL
- Incubation time: 3 h ± 15 min
- Spectrophotometer: microplate reader (ELx800, BioTek Instruments GmbH, Bad Friedrichshall, Germany)
- Wavelength: 570 nm

NUMBER OF REPLICATE TISSUES: 2

CONTROL TISSUES USED IN CASE OF MTT DIRECT INTERFERENCE
The pre-test for direct MTT-reducing capacity of the test item did not result in blue color, i.e. the test item is not a direct MTT reducer.
In the pre-test medium coloration by the test item was observed, but no tissues were stained during the study. Therefore, no additional tissues for color control were treated according to the INVITTOX Protocol SkinEthic™ Skin Corrosivity Test (2012).

NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION: 1

PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if the viability after 3 minutes exposure is less than 50 %, or if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is less than 15 %.
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
TEST MATERIAL
- Amount applied : 20 ± 3 mg

NEGATIVE CONTROL
- Amount applied: 40 ± 3 µL

POSITIVE CONTROL
- Amount applied: 40 ± 3 µL
Duration of treatment / exposure:
3 min or 1 h
Number of replicates:
2

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
3 min
Value:
82.5
Vehicle controls validity:
not examined
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
1 h
Value:
79.89
Vehicle controls validity:
not examined
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: No
- Direct-MTT reduction: No
- Colour interference with MTT: No

ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: Yes
- Acceptance criteria met for positive control: Yes
- Acceptance criteria met for variability between replicate measurements: Yes

Any other information on results incl. tables

Acceptability of the Test

Acceptability of the Negative Control: The negative control OD values were 2.019, 2.059, 1.675 and 1.699 and, thus, in the range of ≥ 0.8 and 3.0.

Acceptability of the Positive Control: After treatment with the positive control (potassium hydroxide, 8N) the mean viability value was 0.59 % after 1 hour exposure and, thus, lower than 15 %.

Test Substance Data Acceptance Criteria: The range between identically treated tissues was less than 30 % (27.10 % after 3 minutes exposure and 13.63 % after 1 hour exposure).

The study met all acceptance criteria

Table 1: Results

Group

Tissue 1

Tissue 2

Mean

CV

OD

Viability (%)

OD

Viability (%)

OD

Viability (%)

Viability (%)

Negative Control

3 min

20.19

99.02

2.059

100.98

2.039

100.00

1.39

1 h

1.675

99.30

1.699

100.70

1.687

100.00

0.99

Positive Control

1 h

0.009

0.51

0.011

0.66

0.010

0.59

17.90

Test Substance

3 min

1.481

72.66

1.883

92.35

1.682

82.50

16.88

1 h

1.262

74.79

1.434

84.99

1.348

79.89

9.02

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
In an in vitro skin corrosion assay (RhE) according to OECD Guideline 431, the test item showed no skin corrosive potential.
Executive summary:

In an in vitro skin corrosion assay (RhE) according to OECD Guideline 431, the potential of the test item to induce skin corrosion in an in vitro human skin model was investigated.

The test item was applied topically to a human reconstructed skin model followed by determination of the cell viability. Cell viability was determined by enzymatic conversion of vital dye MTT into a blue formazan salt and measurement of the formazan salt after extraction from tissues. The percent reduction of cell viability in comparison to untreated negative controls was used to predict the skin corrosion potential.

Duplicates of the human skin RHE-model were treated with the test item or the negative control for 3 minutes and additional 1 hour. Duplicates with the positive control were only treated for 1 hour. 40 ± 3 µL of either the negative control (deionised water) or the positive control (potassium hydroxide, 8N) were applied to the tissues. Before application of 20 ± 3 mg of the solid test item, 20 ± 2 µL of deionised water was spread to the epidermis surface to improve the contact between the test item and the epidermis.

After treatment with the negative control (deionised water) the mean OD per tissue replicate was 2.019 and 2.059 after 3 minutes exposure and 1.675 and 1.699 after 1 hour exposure (study acceptance criterion: 0.8 and 3.0). Treatment with the positive control (Potassium hydroxide, 8N) revealed a mean viability of 0.59% after 1 hour (study acceptance criterion: < 15%). Therefore, the study fulfilled the validity criteria.

Following treatment with the test item, the tissue viability was > 50% after 3 minutes exposure (mean viability: 82.50%) and > 15% after 1 hour exposure (mean viability: 79.89%), i.e. according to OECD 431 the test item is considered as non-corrosive to skin.