Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February - May 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The study was conducted according to an internationally recognised method. Test substance is adequately characterised. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes
Type of method:
static method
Remarks on result:
other: study on going
Conclusions:
Study on going
Executive summary:

The study on going is performed in order to determine the vapour pressure of test item according to OCED 104, resp. EU A.4 guideline, using the static method.

Description of key information

Study on going.

Key value for chemical safety assessment

Additional information

A fully reliable experimental study (still on going), conducted according to OECD 104 /EU A4 guideline, using static method, is going to be available.

It is considered as a key study and the result is going to be retained as key data.