Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 APR 2013 - 28 MAY 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
European Commission Regulation (EC) No. 440/2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
2006
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: OECD 113 Screening test for thermal stability and stability in air
Version / remarks:
1981
Deviations:
no
GLP compliance:
no
Type of method:
effusion method: Knudsen cell
Temp.:
25 °C
Vapour pressure:
0 hPa

Thermal Stability

The DSC-measurement before testing the vapour pressure with the test item in closed glass crucibles showed an endothermal effect in the temperature range of 260-340 °C. In the temperature range of 340- 450 °C an unsteady baseline occurred.

Vapour pressure balance (Effusion method)

The vapour pressure was measured in the temperature range of 40 °C to 70 °C. The following table shows the measured vapour pressure data at the corresponding temperatures.

Temperature [°C]  Vapour pressure [hPa]
 40  3.7 x 10-5
 45  7.4 x 10-5
 50  1.1 x 10-4

 55

 1.2 x 10-4
 60  1.9 x 10-4
 65  7.4 x 10-5

 70

1.4 x 10-4

The data of the vapour pressure measurement showed an unusual behaviour. This is maybe related to the thermal behaviour detected in the pre-test. Therefore the regression to determine the coefficient of the Antoine equation A, B, C was done with the data in the temperature range of 40 - 60 °C. This is a conservative estimation of the vapour pressure of the test item.

Figure 2 (attached as background material) gives the vapour pressure (logarithmic scale) as a function of the inverse temperature (1/T, T in Kelvin). Only for better readability the temperature is also reported in a centigrade scale. The values for 20, 25 and 50 °C are calculated, using the Antoine constants A, B and C as shown there.

Conclusions:
The vapour pressure of the test item is calculated by extrapolation:
20 °C: 0.00000075 hPa
25 °C: 0.000012 hPa
50 °C: 0.000093 hPa
Executive summary:

The vapour pressure of the sample was tested according to EU Method A.4 and OECD Guideline 104 in a non-GLP study with the effusion method.

The vapour pressure of the test item is calculated by extrapolation:

20 °C: 0.00000075 hPa

25 °C: 0.000012 hPa

50 °C: 0.000093 hPa

Description of key information

The vapour pressure of the sample was tested according to EU Method A.4 and OECD Guideline 104 in a non-GLP study with the effusion method.

The vapour pressure of the test item is calculated by extrapolation:

20 °C: 0.00000075 hPa

25 °C: 0.000012 hPa

50 °C: 0.000093 hPa

Key value for chemical safety assessment

Vapour pressure:
0 hPa
at the temperature of:
25 °C

Additional information

The values for 20, 25 and 50 °C are calculated, using the Antoine constants.