Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 17, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
no guideline followed
Principles of method if other than guideline:
Laser light scattering. The test was performed according to the SOP - STR 071 Ed. 01 (Hydro 2000S-A) protocol.
The particle size distribution was analyzed using the Mastersizer 2000 tool, which uses the technique of laser diffraction to measure the size of particles. It measures the intensity of light scattered as a laser beam passes through a dispersed particulate sample. This data is then analyzed to calculate the size of the particles that created the scattering pattern.
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
ca. 1.427 µm
Remarks on result:
other: after 2 minutes of ultrasonic treatement
Percentile:
D50
Mean:
ca. 29.777 µm
Remarks on result:
other: after 2 minutes of ultrasonic treatement
Percentile:
D90
Mean:
ca. 93.092 µm
Remarks on result:
other: after 2 minutes of ultrasonic treatement

The analysis has been run after 2 minutes of ultrasonic treatement.

Conclusions:
MD10 = 1.427 µm;
MD50 = 29.777 µm;
MD90 = 93.092 µm.
Executive summary:

Methods:


The substance has been tested for granulometry by the volumetric distribution. The particle size distribution was analyzed using the Mastersizer 2000 tool, which uses the technique of laser diffraction to measure the size of particles. It measures the intensity of light scattered as a laser beam passes through a dispersed particulate sample. This data is then analyzed to calculate the size of the particles that created the scattering pattern.


 


Results:


MD10 = 1.427 µm


MD50 = 29.777 µm


MD90 = 93.092 µm

Description of key information

MD10 = 1.427 µm


MD50 = 29.777 µm


MD90 = 93.092 µm

Additional information

Laser light scattering