Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019-03-11 to 2019-03-20
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
OECD Guidelines for the Testing of Chemicals No. 104: "Vapour Pressure", March 23, 2006
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
EC No. 761/2009, Part A: Methods for Determination of Physico-Chemical Properties, Guideline A.4: “Vapour Pressure”, Official Journal of the European Union No. L220, August 24, 2009
GLP compliance:
no
Type of method:
effusion method: isothermal thermogravimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
2-{5-fluoro-1-[(2-fluorophenyl)methyl]-1H-pyrazolo[3,4-b]pyridin-3-yl}-5-[(1E)-2-phenyldiazen-1-yl]pyrimidine-4,6-diamine
EC Number:
811-933-5
Cas Number:
1350653-29-0
Molecular formula:
C23 H17 F2 N9
IUPAC Name:
2-{5-fluoro-1-[(2-fluorophenyl)methyl]-1H-pyrazolo[3,4-b]pyridin-3-yl}-5-[(1E)-2-phenyldiazen-1-yl]pyrimidine-4,6-diamine
Test material form:
solid

Results and discussion

Vapour pressure
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
ca. 0 Pa
Remarks on result:
other: The vapour pressure of the test item was estimated to be below 10-10 Pa at 20 °C (6.03 x 10^-13 Pa).

Any other information on results incl. tables

The isothermal thermogravimetrical effusion method was applied for the determination of the vapour pressure of Fluorazopyrimidin.

A value of the vapour pressure of the test item was determined using the data obtained between 250 °C and 280 °C. The vapour pressure of the test item was estimated to be below 10-10 Pa at 20 °C (6.03 x 10-13 Pa).

Applicant's summary and conclusion

Conclusions:
The isothermal thermogravimetrical effusion method was applied for the determination of the vapour pressure of Fluorazopyrimidin.
A value of the vapour pressure of the test item was determined using the data obtained between 250 °C and 280 °C. The vapour pressure of the test item was estimated to be below 10-10 Pa at 20 °C (6.03 x 10-13 Pa).
Executive summary:

Title:

Fluorazopyrimidin: Determination of the Vapour Pressure by Isothermal Thermogravimetry

 

Purpose:

The purpose of this study was to determine the vapour pressure of the test item using the isothermal thermogravimetrical effusion method.

 

Guidelines / Recommendations:

This study was designed to comply with the following methods:

European Community (EC), EC No. 761/2009, A.4: “Vapour Pressure”, 2009

Organisation for Economic Co-operation and Development (OECD), OECD Guidelines for the Testing of Chemicals No. 104: “Vapour Pressure”, 2006

 

Results / Conclusion:

The isothermal thermogravimetrical effusion method was applied for the determination of the vapour pressure of Fluorazopyrimidin.

A value of the vapour pressure of the test item was determined using the data obtained between 250 °C and 280 °C. The vapour pressure of the test item was estimated to be below 10-10 Pa at 20 °C (6.03 x 10-13 Pa).

This study is classified acceptable and satisfies the guideline requirements for vapour pressure studies.