Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 25, 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
no
Type of method:
pycnometer method
Type:
relative density
Density:
ca. 1.692
Temp.:
20 °C

Relative density (D204) is calculated as: δsubs/ 0.999973

  1sttest 2ndtest Media
WP1 39.5503 g 38.8164 g    
WHP 72.4822 g 71.8098 g    
WH1 32.9319 g 32.9934 g    
dHex 0.659 g/cm3 0.66 g/cm3 0.6595 g/cm3
Vol Pic 50 cm3 50 cm3    
WP2 39.5499 g 39.8167 g    
WSP 44.6811 g 43.8361 g    
WS 5.1312 g 5.0194 g    
WSH 36.0645 g 36.056 g    
WH2 30.9333 g 31.0366 g    
Vhex 46.9656 cm3 47.0346 cm3    
Vsubs 3.0344 cm3 2.9654 cm3    
dsubs 1.691 g/cm3 1.693 g/cm3 1.692 g/cm3
Relative density (δ20/4) 1.692  
Standard deviation
0.0012  
Relative standard deviation 0.07  
Conclusions:
Relative Density = 1.692
Executive summary:

Method

Relative density was determined by means of pycnometer method as per recommendations of OECD 109. Density was calculated from the difference in weight between the full and empty pycnometer and its volume.

Result

Relative density: 1.692 at 20 °C

Description of key information

Relative density = 1.692

Key value for chemical safety assessment

Relative density at 20C:
1.692

Additional information

Pycnometer method - OECD 109