Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures:

Pay attention to self-protection.
Remove victims from hazardous area.
Immediately remove soiled or soaked clothing and remove it to a safe distance.
Keep victim warm, in a stabilized position and covered.
Do not leave victims unattended.
If the casualty is unconscious: Place the victim in the recovery position.

Inhalation:
Inhalation is possible if aerosols, mists, dusts, or smoke form.
Move victims into fresh air.
With labored breathing: Provide with oxygen.
Consult a doctor.
If the casualty is not breathing: Perform mouth-to-mouth resuscitation, notify emergency physician immediately.

Skin contact:
Wash off affected area immediately with plenty of water for at least 15 minutes.
If symptoms persist, consult a physician for treatment.

Eye contact:
With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.
In case of persistent discomfort: Consult an ophthalmologist.

Ingestion:
Rinse mouth.
Immediately give large quantities of water to drink.
Obtain medical attention.

Most important symptoms and effects, both acute and delayed:

Symptoms:
None known.

Hazards:
Other dangerous properties can not be excluded.

Indication of any immediate medical attention and special treatment needed:

This substance does not have any noteworthy noxious potential. Damage to health is thus not expected.

Fire-fighting measures

Extinguishing media:
Suitable extinguishing media:
Water spray, foam, CO2, dry powder.

Unsuitable extinguishing media:
Do not use a solid water stream as it may scatter and spread fire.

Special hazards arising from the substance or mixture:
May be released in case of fire: carbon monoxide, carbon dioxide.
Organic products of decomposition:
Flammable smouldering gases, nitrogen oxides (NOx).
In case of fire cool endangered containers with water.

Advice for firefighters:
Contaminated extinguishing water must be treated at a suitable disposal plant in accordance with waste management laws.
In case of fire, remove the endangered containers and bring to a safe place, if this can be done safely.
Keep out unprotected persons.
In the event of fire, wear self-contained breathing apparatus.
Full protective suit.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Do not breathe in vapours or aerosols.
Keep unauthorized persons away.
Assure sufficient ventilation.

Environmental precautions:
Prevent substance from entering soil, natural bodies of water and sewer systems.
If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and material for containment and cleaning up:
Pick up with suitable adsorbent material.
Pack and label wastes like the pure substance.
Do not detach label from the delivery containers prior to disposal.
Disposal according to local authority regulations.
Wear personal protective equipment.

Handling and storage

Precautions for safe handling:
Use permissible in closed systems only.
Handle and transfer product in closed systems only (gas displacement device).
Ensure that apparatus and pipelines are free from leaks.
Do not ventilate into the open.
Suitable loading and unloading device required.

Conditions for safe storage, including any incompatibilities:
Advice on protection against fire and explosion.
Keep away from combustion sources such as sparks, flames and unprotected light sources.
Normal measures for preventive fire protection.

Storage:
Store in the original receptacle, keeping this tightly sealed, under cool and dry conditions.

Further information:
Protect from sunlight, warmth and heat.
In order to ensure due transportation, make certain that stacks are of the correct height, containers are securely fastened so as not to fall off, and labelled according to the regulations.

Advice on common storage:
Observe prohibition against storing together!

German storage class:
10 - Combustible liquids.

Specific end use(s):
We are unaware of any specific end uses which go beyond the data reported in section 1 of the safety data sheet.

Transport information

Land transport (UN RTDG/ADR/RID)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Inland waterway transport (UN RTDG/ADN(R))

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters:

DNEL/DMEL values:
Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

PNEC values:
Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

Exposure controls:
Engineering measures:
Refill and handle product only in closed system.
Leak detection recommended.
Do not add wastewater to a biological wastewater treatment plant.
Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.
All precautionary measures indicated have to be observed.

Exposure controls:
The substance must be handled under strictly controlled conditions in accordance with Article 17/18 of the REACH regulation.

Personal protective equipment:
Respiratory protection:
Use suitable respiratory protection where aerosols/vapours are generated.
Respirator with brown A-type filter.
Accidental release measures:
In case vapors or aerosols appear:
Wear a self contained respiratory apparatus.
Note time limit for wearing respiratory protective equipment.

Hand protection:
Glove material Nitrile, for example, Dermatril P 743, Kächele-Cama Latex GmbH (KCL), Germany
Material thickness: 0.2 mm
Method DIN EN 374.
Accidental release measures:
Glove material Nitrile/Chloroprene, for example, Nitopren 717, Kächele-Cama Latex GmbH (KCL), Germany
Material thickness: 0.65 mm
Method DIN EN 374.
Selection of protective gloves to meet the requirements of specific workplaces.
Suitability for specific workplaces should be clarified with protective glove manufacturers.
The information is based on our own tests, references from the literature and information from glove manufacturers, or derived by analogy with similar materials.
Remember that the useful time per day of a chemical protection glove may be much shorter than the permeation time determined according to EN 374 due to the many different influential factors involved (e.g. temperature).

Eye protection:
Safety glasses with side-shields conforming to EN166.
Accidental release measures:
Goggles.

Skin and body protection:
Usual lab protective clothing.
Accidental release measures:
Chemical protective suit, disposable protective suit.

Hygiene measures:
Avoid contact with skin, eyes and clothing.
Wash contact areas after handling.
Take off clothing and shoes contaminated with product. Clean before reuse.
Do not eat, drink, smoke, or sniff while at work.
Wash your hands and/or face before breaks and before termination of work.

Protective measures:
All precautionary measures indicated have to be observed.
Risk assessment and risk monitoring of all work places required.
Health, Safety and Emergency Management System recommended.
Regular safety training is a must.
Written approval necessary in case of non-routine jobs, e.g. maintenance activities.

Environmental exposure controls:
In some cases, exhaust air scrubbers, filters or technical changes to the processing plant will be required in order to decrease emissions to acceptable values.

Stability and reactivity

Stability and reactivity:

Reactivity:
No further information available.

Chemical stability:
No further information available.

Possibility of hazardous reactions:
No further information available.

Conditions to avoid:
Sun rays, heat, heat effect
Keep away from heat and sources of ignition.

Incompatible materials:
Strong oxidizing agents.

Hazardous decomposition products:
No further information available.

Disposal considerations

Waste treatment methods:

Product:
Strictly controlled conditions during disposal or treatment to air, wastewater and waste.
Do not add wastewater to a biological wastewater treatment plant.
Disposal according to local authority regulations.
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.

Uncleaned packaging:
Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.