Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 23-03-2009 to 25-05-2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
yes (incl. QA statement)
Remarks:
Harlan Laboratories Ltd, Zelgliweg 1, 4452 Itingen, Switzerland
Type of method:
closed cup
Remarks:
Pensky-Marten closed flash point tester
Flash point:
> 114 °C
Atm. press.:
99.8 kPa

The test item was heated from 30 °C to 114 °C. The test was stopped when the test item started boiling. The atmospheric pressure on the day of the measurement was 99.8 kPa. The preliminary test was performed in duplicate.

No flash point was observed in this temperature range.

Interpretation of results:
GHS criteria not met
Executive summary:

The purpose of the study was to evaluate the flash point of Glyoxylic Acid 50 %.

No flash point was found using the Pensky-Martens flash point apparatus in the temperature range between 30 °C and 114 °C.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
1993
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Directive 84/449/EEC
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point:
> 115 °C

No flash point before 115 °C; at that temperature, no decomposition was observed.

Interpretation of results:
GHS criteria not met

Description of key information

There is no flash point up to the boiling point of 114 °C.

Key value for chemical safety assessment

Additional information

No flash point was found for Glyoxylic Acid 50% using the Pensky-Martens flash point apparatus in the temperature range between 30 °C and 114 °C (= boiling point of the test item).