Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
density, other
Remarks:
information as provided from data source
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-09-23 to 2010-09-27
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. A GLP study which refers to DIN EN ISO 2811, which succeeds DIN 53217 referenced in EU test method L383 A/21-25 (EU A.3).
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Type:
relative density
Density:
ca. 1.471
Temp.:
20 °C
Remarks on result:
other: relative to the same volume of water at 4 oC
Executive summary:

Relative Density of additive Ni-1 was determined using the pycnometer method (EU A.3) according GLP.

Result: Density at 20 °C compared to water at 4°C = 1.471.

Description of key information

Relative Density of additive Ni-1 (compared to the same volume of water at 4°C) was determined using the pycnometer method (EU A.3) according GLP.

Key value for chemical safety assessment

Relative density at 20C:
1.471

Additional information