Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 November 2016 - 17 March 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes
Specific details on test material used for the study:
- Batch n°: I16CB1581
- Analytical purity: 98.61 %
- Expiration date: 2019-04-04
- Storage condition: at room temperature
Key result
Remarks on result:
no self-ignition observed up to the melting point
Conclusions:
Based on the results of the EC A.16 test performed, the test item is considered not a self-heating substance.
Endpoint:
auto-ignition temperature, other
Remarks:
Minimum ignition temperature dust cloud (BAM oven)
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: Documentation insufficient for assessment. No information on purity of the substance.
Qualifier:
according to guideline
Guideline:
other: VDI Guideline 2263 Part 1: Ignition Temperature BAM-oven
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
other: ESCIS Expert Commission for Safety in the Swiss Chemical Industry, Booklet 1 ''Sicherheitstests fur Chemikalien''.
Deviations:
not specified
GLP compliance:
not specified

The Minium Ignition Temperature determined in the BAM oven is 390 deg C.

Conclusions:
The Minimum Ignition Temperature determined in the BAM oven for T003066 is 390 deg C.

Description of key information

The auto-flammability potential of T003066 was determined in a K1 GLP study (Reingruber, 2017) carried out according to EC A.16. In the EC A.16 test no self-heating was observed up to the melting point of the test item. No relative self-ignition temperature could be determined.

Key value for chemical safety assessment

Additional information

There is a supporting study available, for which the reliability was not assignable (K4) performed by the Process Safety Center of Janssen Pharmaceutica in which an MIT dust cloud (BAM) study was performed reporting a minimum ignition temperature of the dust cloud is of 390°C (2008).