Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 December 2017 to 13 December 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
yes
Type of method:
method to determine freezing temperature

Test material

Constituent 1
Chemical structure
Reference substance name:
4-methylpentan-2-one oxime
EC Number:
203-298-2
EC Name:
4-methylpentan-2-one oxime
Cas Number:
105-44-2
Molecular formula:
C6H13NO
IUPAC Name:
4-methylpentan-2-one oxime
Test material form:
liquid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 2017 494

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
< -20 °C
Remarks on result:
other: Mean of at least two measurements which are in the range of the estimated accuracy of +-0.5°C.

Any other information on results incl. tables

The mean of at least two measurements, which are in the range of the estimated accuracy of +-0.5°C is reported as the freezing temperature/range.

The temperature range of the equipment is -20°C to 150°C.

During evaluation run the sample was held at -27°C for approximately 24 hours, no phase change was observed. Therefore the test was discontinued.