Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 03. May 2016 to 18. May 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Remarks:
Epi Ocular (TM) Human Cornea Model

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
Version / remarks:
adopted Jul. 2015
Deviations:
no
Principles of method if other than guideline:
Normal, human-derived kratinocytes are cultured to form a stratified, squamous epithelium consisting of highly organised basal cells, similar to the human cornea. Eye irritant materials are defined by an decrease of cell viability. The cell viability is measured by dehydrogenase (present in all mitochondria) conversion of MTT (3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazoliumbromide) int a blue formazan salt, which can be determined quantitatively by a plate spectral photometer at 570nm.
GLP compliance:
yes (incl. QA statement)
Remarks:
certified by Landesamt für Umwelt, Wasserwirtschaft und Gewerbeaufsicht, Kaiser-Friedrich-Str. 7, D-55116 Mainz, Germany

Test material

Constituent 1
Chemical structure
Reference substance name:
reaction product of alumina and sulfuric acid
EC Number:
812-508-7
Cas Number:
1093112-19-6
Molecular formula:
unspecified, UVCB substance
IUPAC Name:
reaction product of alumina and sulfuric acid
Test material form:
solid: particulate/powder

Test animals / tissue source

Species:
human
Strain:
other: keratinocytes, forming an epithelium similar to a human cornea
Remarks:
EpiOcular(TM) kit, derived from MatTek, In Vitro Life Science Laboratories, Mylinskè Nivy 73, 82105 Bratislava, Slovakia
Details on test animals or tissues and environmental conditions:
The tissues are cultured in specially prepared cell culture insert with aporus membrane through which nutrients can pass.
The tissue surface is 0.6 cm².
The cells are not transformed or infected with genes to induce an extended life span.

Test system

Vehicle:
unchanged (no vehicle)
Amount / concentration applied:
Tissue 1: 53.6 mg
Tissue 2: 48.5 mg
Duration of treatment / exposure:
6 h
Duration of post- treatment incubation (in vitro):
25 min. post soak, 18h post treatment incubation
Number of animals or in vitro replicates:
2 x 2
Details on study design:
blank: isopropanol, measured in 8 wells
negative control: water
positive control: methyl acetate

Results and discussion

In vitro

Results
Irritation parameter:
in vitro irritation score
Remarks:
relative absorbance values [%]
Run / experiment:
2 concentrations in duplicate
Value:
>= 0 - <= 99.1
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation

Applicant's summary and conclusion

Conclusions:
In the EpiOcular(TM) Eye Irritation Test Sulfuric acid, reaction product with alumina is considerd as not eye irritant.