Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-07-31
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Butanoic acid, 4-amino-4-oxosulfo-, N-coco alkyl derivs., monosodium salts, compds. with triethanolamine
EC Number:
308-662-5
EC Name:
Butanoic acid, 4-amino-4-oxosulfo-, N-coco alkyl derivs., monosodium salts, compds. with triethanolamine
Cas Number:
98171-53-0
IUPAC Name:
Butanoic acid, 4-amino-4-oxosulfo-, N-coco alkyl derivs., monosodium salts, compds. with triethanolamine
Test material form:
solid
Specific details on test material used for the study:
Name of test substance: Efka FA 4600 (solvent free)
Test substance No.: 16/0407-1
Batch identification: 0015567151
CAS No.: 98171-53-0
Identity: Confirmed (pre information from Competence Center Analytics (BASF SE)
Content: approx. 95 %
Homogeneity: Homogeneous
Storage stability: Expiry date: 11 Jan 2018
The stability of the test substance under storage conditions over the test period was guaranteed by the sponsor, and the sponsor holds this responsibility. The test facility is organizationally independent from BASF SE sponsor division.
Physical state/
Appearance: Solid/light yellow

Sampling and analysis

Analytical monitoring:
yes

Test solutions

Vehicle:
no
Details on test solutions:
The test substance was added in the required amounts according to the test concentrations directly to the test vessels with 234 mL deionized water. Aliquots of the reference substance
stock solution were dosed to the test vessels and made up with deionized water to a volume of 234 mL. 16 mL synthetic medium were dosed to each test vessel with test substance and
reference substance afterwards. To prepare the blank control assays 234 mL of deionized water and 16 mL synthetic medium were mixed. The pH-values in all test vessels were checked. An adjustment was not necessary.
After addition of 250 mL of inoculum suspension (3 g/L DW) the incubation was started by aeration of the test vessels with pressured air. The vessels for the blank control assays were
prepared to the same procedure without addition of test- or reference substance. Due to foaming of the test substance test assays 25μL tributyl phosphate/test assay were added to all
test assays as antifoam agent.
After 3 hours incubation at 20 ± 2°C the mixtures in the test vessels were placed subsequently for oxygen measuring. The temperature was measured for seven times in a separate vessel filled with aerated deionized water during incubation phase. The content of oxygen at the start
of the measurements was > 7 mg/L with the exception described below.
The total oxygen consumption was measured in the sequence BC1-3 and RS1, RS2-5, RS6
and TS1-3, TS4-7, TS8-11 and TS12-15. The oxygen consumption of the blank control BC4-6 were measured at last. No abiotic control was tested. The oxygen uptake was measured for a period of about 8 to 10 minutes.

Test organisms

Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
Test system: Activated sludge from a municipal wastewater treatment plant.
Origin of the test system: Municipal wastewater treatment plant of Mannheim, Germany

Study design

Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h

Test conditions

Test temperature:
21.4 – 21.9 °C
pH:
7.4
Dissolved oxygen:
Oxygen concentration during aeration: > 2 mg/L
Oxygen concentration immediately before measurement: > 7 mg/L
Nominal and measured concentrations:
1000, 500, 250, 125, 62.5 mg/L as nominal concentration based on test substance without correction of purity and blank controls.
Details on test conditions:
TEST SYSTEM
Test system: municipal Activated sludge Reason for the selection of the test system: required by the test guidelines
Age: 1 day
Origin: aeration tank of the wastewater treatment plant of Mannheim, Germany
Collection of the test system: 31 Jul 2017
Arrival in the test facility: 31 Jul 2017
After arrival of the activated sludge suspension in the test facility the suspension was sieved with a fine woven mesh (mesh size about 1 mm). This suspension was pre-aerated over night at room temperature. At the next day the sludge suspension was washed once with
drinking water and the suspension was adjusted to 3 g/L Dw.

Test replicates: 6 replicates for the control,
3 replicates for each test substance concentration,
2 replicates for each reference substance concentration.
Reason for selection of test concentrations:
According to the test guidelines, at least 5 concentrations in a geometric series with a separation factor of ≤ 3.2 should be used, preferably encompassing the range from 10 – 80% inhibition .

Test conditions
Incubation time: 3 hours
Test temperature: 21.4 – 21.9 °C
Test vessels: Glas-beakers (nominal volume 1L)
Test volume: 500 mL
Synthetic medium: 16 mL/test vessel of 100-fold concentrated OECD medium
Oxygen concentration during aeration: > 2 mg/L
Oxygen concentration immediately before measurement: > 7 mg/L
Duration of the measurement of oxygen consumption:
About 8 - 10 min
Sludge concentration in the test vessel: 1.5 g/L Dw
Reference substance (positive control):
yes

Results and discussion

Effect concentrationsopen allclose all
Key result
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Key result
Duration:
3 h
Dose descriptor:
EC10
Effect conc.:
84 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Key result
Duration:
3 h
Dose descriptor:
other: EC20
Effect conc.:
550 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Results with reference substance (positive control):
The EC50 of the reference substance 3,5-dichlorophenol was in the range of 2-25 mg/L in 3 hours.

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Executive summary:

The toxicity of the test item towards microorganisms (activated sewage sludge predominately domestic) was tested in an OECD 209 for 3h. The EC50 was determined to be > 1000 mg/l, the EC20 was > 550 mg/l and the EC10 was 84 mg/l.