Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 May 2016 to 12 July 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

PRELIMINARY SCREENING

- The pile failed to ignite during the 2 minutes that the Bunsen flame was applied.

- The result of the preliminary screening test obviated the need to perform the main test.

Interpretation of results:
GHS criteria not met
Conclusions:
The test item was determined not to be a highly flammable solid as it failed to ignite in the preliminary screening test.
Executive summary:

GUIDELINE

Flammability was investigated by measuring the burning rate of test item prepared as a pile of set dimensions. Testing was conducted using a procedure designed to be compatible with Method A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 (30 May 2008).

RESULTS

The test item was determined not to be a highly flammable solid as it failed to ignite in the preliminary screening test.

Description of key information

The test item was determined not to be a highly flammable solid as it failed to ignite in the preliminary screening test (EU Method A.10).

Key value for chemical safety assessment

Flammability:
not classified

Additional information

GUIDELINE

Flammability was investigated by measuring the burning rate of test item prepared as a pile of set dimensions. Testing was conducted using a procedure designed to be compatible with Method A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 (30 May 2008).

RESULTS

The test item was determined not to be a highly flammable solid as it failed to ignite in the preliminary screening test.

Justification for classification or non-classification

The test item failed to ignite in the preliminary screening test and does not meet the criteria for classification as a flammable solid under the terms of Regulation (EC) No 1272/2008.